IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v14y2021i24p8544-d705525.html
   My bibliography  Save this article

How to Adapt Mongolian Yurt to the Modern Requirements and European Climate—Airtightness versus CO 2 Concentration?

Author

Listed:
  • Tomasz Kisilewicz

    (Faculty of Civil Engineering, Cracow University of Technology, Warszawska 24, 31-155 Krakow, Poland)

  • Katarzyna Nowak-Dzieszko

    (Faculty of Civil Engineering, Cracow University of Technology, Warszawska 24, 31-155 Krakow, Poland)

  • Katarzyna Nowak

    (Faculty of Civil Engineering, Cracow University of Technology, Warszawska 24, 31-155 Krakow, Poland)

  • Sabina Kuc

    (Faculty of Architecture, Cracow University of Technology, Warszawska 24, 31-155 Krakow, Poland)

  • Ksenia Ostrowska

    (Faculty of Mechanical Engineering, Cracow University of Technology, Warszawska 24, 31-155 Krakow, Poland)

  • Piotr Śliwiński

    (Faculty of Civil Engineering, Cracow University of Technology, Warszawska 24, 31-155 Krakow, Poland
    Doctoral Student.)

Abstract

There are currently trends in the world to transfer and adapt traditional solutions to contemporary needs. This applies, inter alia, to mobile shelters used by nomadic peoples. The article is devoted to the research on the quality of internal air in the yurt and the possibilities of its adaptation to high contemporary quality and environmental requirements, while maintaining its characteristic sustainable values. The tested traditional Mongolian yurt was moved from the dry and cold climate of the Asian steppe to the temperate climate of Central Europe and has been significantly modified. The outer shell materials have been changed, replacing natural materials with modern tight insulating foils. The wood-fired stove has been replaced with an electric heater and the roof opening has been firmly closed. All of these modifications resulted in far-reaching changes in the quality of the internal environment in the yurt. The conducted measurements and simulations of CO 2 concentration in the modified yurt proved that the efficiency of ventilation system is not sufficient and that the air quality is very poor (even for a single user). In the case of a larger number of users, the concentration of CO 2 has already reached a level that was dangerous to health. The simplest method of improving the air quality in the yurt is its careful unsealing to the required level. Striving for a low energy demand, however, would require a completely different approach (for example, in the form of forced ventilation with a heat recovery unit, ultimately powered with a PV array). Such a solution is very different from the traditional yurt model but is close to modern expectations and environmental requirements.

Suggested Citation

  • Tomasz Kisilewicz & Katarzyna Nowak-Dzieszko & Katarzyna Nowak & Sabina Kuc & Ksenia Ostrowska & Piotr Śliwiński, 2021. "How to Adapt Mongolian Yurt to the Modern Requirements and European Climate—Airtightness versus CO 2 Concentration?," Energies, MDPI, vol. 14(24), pages 1-18, December.
  • Handle: RePEc:gam:jeners:v:14:y:2021:i:24:p:8544-:d:705525
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/14/24/8544/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/14/24/8544/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Guoqiang Xu & Hong Jin & Jian Kang, 2019. "Experimental Study on the Indoor Thermo-Hygrometric Conditionsof the Mongolian Yurt," Sustainability, MDPI, vol. 11(3), pages 1-20, January.
    2. Małgorzata Fedorczak-Cisak & Alicja Kowalska-Koczwara & Krzysztof Nering & Filip Pachla & Elżbieta Radziszewska-Zielina & Grzegorz Śladowski & Tadeusz Tatara & Bartłomiej Ziarko, 2019. "Evaluation of the Criteria for Selecting Proposed Variants of Utility Functions in the Adaptation of Historic Regional Architecture," Sustainability, MDPI, vol. 11(4), pages 1-29, February.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Małgorzata Fedorczak-Cisak & Alicja Kowalska-Koczwara & Filip Pachla & Elżbieta Radziszewska-Zielina & Bartłomiej Szewczyk & Grzegorz Śladowski & Tadeusz Tatara, 2020. "Fuzzy Model for Selecting a Form of Use Alternative for a Historic Building to be Subjected to Adaptive Reuse," Energies, MDPI, vol. 13(11), pages 1-24, June.
    2. Elżbieta Radziszewska-Zielina & Dagmara Adamkiewicz & Bartłomiej Szewczyk & Olga Kania, 2022. "Decision-Making Support for Housing Projects in Post-Industrial Areas," Sustainability, MDPI, vol. 14(6), pages 1-26, March.
    3. Piotr Michalak, 2021. "Selected Aspects of Indoor Climate in a Passive Office Building with a Thermally Activated Building System: A Case Study from Poland," Energies, MDPI, vol. 14(4), pages 1-22, February.
    4. Marek Dudzik, 2020. "Towards Characterization of Indoor Environment in Smart Buildings: Modelling PMV Index Using Neural Network with One Hidden Layer," Sustainability, MDPI, vol. 12(17), pages 1-37, August.
    5. Teng Shao & Wuxing Zheng & Hong Jin, 2020. "Analysis of the Indoor Thermal Environment and Passive Energy-Saving Optimization Design of Rural Dwellings in Zhalantun, Inner Mongolia, China," Sustainability, MDPI, vol. 12(3), pages 1-34, February.
    6. Małgorzata Fedorczak-Cisak & Anna Kotowicz & Elżbieta Radziszewska-Zielina & Bartłomiej Sroka & Tadeusz Tatara & Krzysztof Barnaś, 2020. "Multi-Criteria Optimisation of an Experimental Complex of Single-Family Nearly Zero-Energy Buildings," Energies, MDPI, vol. 13(7), pages 1-30, March.
    7. Mark Bomberg & Anna Romanska-Zapala & Paulo Santos, 2023. "The 4th Industrial Revolution Brings a Change in the Design Paradigm for New and Retrofitted Buildings," Energies, MDPI, vol. 16(4), pages 1-22, February.
    8. Bożena Orlik-Kożdoń & Elżbieta Radziszewska-Zielina & Małgorzata Fedorczak-Cisak & Tomasz Steidl & Andrzej Białkiewicz & Maria Żychowska & Andriy Muzychak, 2020. "Historic Building Thermal Diagnostics Algorithm Presented for the Example of a Townhouse in Lviv," Energies, MDPI, vol. 13(20), pages 1-28, October.
    9. Fedorczak-Cisak, Małgorzata & Radziszewska-Zielina, Elżbieta & Białkiewicz, Andrzej & Prociak, Aleksander & Steidl, Tomasz & Tatara, Tadeusz & Żychowska, Maria & Muniak, Damian Piotr, 2022. "Energy efficiency improvement by using hygrothermal diagnostics algorithm for historical religious buildings," Energy, Elsevier, vol. 252(C).
    10. Małgorzata Fedorczak-Cisak & Alicja Kowalska-Koczwara & Krzysztof Nering & Filip Pachla & Elżbieta Radziszewska-Zielina & Piotr Stecz & Tadeusz Tatara & Tomasz Jeleński, 2022. "Measurement and Diagnosis of Comfort in a Historic Building," Energies, MDPI, vol. 15(23), pages 1-28, November.
    11. Małgorzata Fedorczak-Cisak & Elżbieta Radziszewska-Zielina & Bożena Orlik-Kożdoń & Tomasz Steidl & Tadeusz Tatara, 2020. "Analysis of the Thermal Retrofitting Potential of the External Walls of Podhale’s Historical Timber Buildings in the Aspect of the Non-Deterioration of Their Technical Condition," Energies, MDPI, vol. 13(18), pages 1-35, September.
    12. Przemysław Markiewicz-Zahorski & Joanna Rucińska & Małgorzata Fedorczak-Cisak & Michał Zielina, 2021. "Building Energy Performance Analysis after Changing Its Form of Use from an Office to a Residential Building," Energies, MDPI, vol. 14(3), pages 1-24, January.
    13. Michał Piasecki & Elżbieta Radziszewska-Zielina & Piotr Czerski & Małgorzata Fedorczak-Cisak & Michał Zielina & Paweł Krzyściak & Patrycja Kwaśniewska-Sip & Wojciech Grześkowiak, 2020. "Implementation of the Indoor Environmental Quality (IEQ) Model for the Assessment of a Retrofitted Historical Masonry Building," Energies, MDPI, vol. 13(22), pages 1-27, November.
    14. Beata Nowogońska & Magdalena Mielczarek, 2021. "Renovation Management Method in Neglected Buildings," Sustainability, MDPI, vol. 13(2), pages 1-20, January.
    15. Beata Nowogońska, 2020. "Consequences of Abandoning Renovation: Case Study—Neglected Industrial Heritage Building," Sustainability, MDPI, vol. 12(16), pages 1-14, August.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:14:y:2021:i:24:p:8544-:d:705525. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.