Abstract

The energy supply of office buildings and smart homes is a key issue in the global energy system. The growing use of microelectronics-based technology achieves new devices for a more comfortable life and wider use of electronic office equipment. On the one hand, these applications incorporate more and more sensitive electronic devices which are potentially affected by any external electrical transient. On the other hand, the existing electrical loads, which generally use electronic power systems (such as different types of battery chargers, ballasts, inverters, switching power supplies, etc.), generate different kinds of transients in their own electrical internal network. Moreover, improvements in the information of the state of the mains alternating current (AC) power line allows risk evaluation of any disturbance caused to permanently connected electronic equipment, such as computers, appliances, home security systems, phones, TVs, etc. For this reason, it is nowadays more important to introduce monitoring solutions into the electrical network to measure the level of power quality so that it can protect itself when necessary. This article describes a small and compact detector using a low-cost microcontroller and a very simple direct acquiring circuit. In addition; it analyzes different methods to implement various power quality (PQ) surveillance algorithms that can be implemented in this proposed minimum hardware platform. Hence; it is possible to achieve cheap and low-power monitoring devices that can become nodes of a wireless sensor network (WSN). The work shows that using a small computational effort; reasonable execution speed; and acceptable reliability; this solution can be used to detect a variety of large disturbance phenomena and spread the respective failure report through a 433 MHz or 2.4 GHz radio transmitter. Therefore, this work can easily be extended to the Internet of Things (IoT) paradigm. Simultaneously, a software application ( PulsAC ) has been developed to monitor the microcontroller’s real-time progress and detection capability. Moreover, this high-level code (C++ language), allows us to test and debug the different utilized algorithms that will be later run by the microcontroller unit. These tests have been performed with real signals introduced by a function generator and superimposed on the true AC sine wave

Suggested Citation

  • José-María Guerrero-Rodríguez & Clemente Cobos-Sánchez & Juan-José González-de-la-Rosa & Diego Sales-Lérida, 2019. "An Embedded Sensor Node for the Surveillance of Power Quality," Energies, MDPI, vol. 12(8), pages 1-20, April.
  • Handle: RePEc:gam:jeners:v:12:y:2019:i:8:p:1561-:d:225668
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/12/8/1561/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/12/8/1561/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Juan-José González-de-la-Rosa & Agustín Agüera-Pérez & José-Carlos Palomares-Salas & Olivia Florencias-Oliveros & José-María Sierra-Fernández, 2018. "A Dual Monitoring Technique to Detect Power Quality Transients Based on the Fourth-Order Spectrogram," Energies, MDPI, vol. 11(3), pages 1-12, February.
    2. Juan José González De la Rosa & José María Sierra-Fernández & José Carlos Palomares-Salas & Agustín Agüera-Pérez & Álvaro Jiménez Montero, 2015. "An Application of Spectral Kurtosis to Separate Hybrid Power Quality Events," Energies, MDPI, vol. 8(9), pages 1-17, September.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Jose-María Sierra-Fernández & Sarah Rönnberg & Juan-José González de la Rosa & Math H. J. Bollen & José-Carlos Palomares-Salas, 2019. "Application of Spectral Kurtosis to Characterize Amplitude Variability in Power Systems’ Harmonics," Energies, MDPI, vol. 12(1), pages 1-15, January.
    2. Alexandre Serrano-Fontova & Pablo Casals Torrens & Ricard Bosch, 2019. "Power Quality Disturbances Assessment during Unintentional Islanding Scenarios. A Contribution to Voltage Sag Studies," Energies, MDPI, vol. 12(16), pages 1-21, August.
    3. Kewei Cai & Belema Prince Alalibo & Wenping Cao & Zheng Liu & Zhiqiang Wang & Guofeng Li, 2018. "Hybrid Approach for Detecting and Classifying Power Quality Disturbances Based on the Variational Mode Decomposition and Deep Stochastic Configuration Network," Energies, MDPI, vol. 11(11), pages 1-18, November.
    4. Misael Lopez-Ramirez & Luis Ledesma-Carrillo & Eduardo Cabal-Yepez & Carlos Rodriguez-Donate & Homero Miranda-Vidales & Arturo Garcia-Perez, 2016. "EMD-Based Feature Extraction for Power Quality Disturbance Classification Using Moments," Energies, MDPI, vol. 9(7), pages 1-15, July.
    5. Juan-José González-de-la-Rosa & Agustín Agüera-Pérez & José-Carlos Palomares-Salas & Olivia Florencias-Oliveros & José-María Sierra-Fernández, 2018. "A Dual Monitoring Technique to Detect Power Quality Transients Based on the Fourth-Order Spectrogram," Energies, MDPI, vol. 11(3), pages 1-12, February.
    6. María-Ángeles Cifredo-Chacón & Fernando Perez-Peña & Ángel Quirós-Olozábal & Juan-José González-de-la-Rosa, 2019. "Implementation of Processing Functions for Autonomous Power Quality Measurement Equipment: A Performance Evaluation of CPU and FPGA-Based Embedded System," Energies, MDPI, vol. 12(5), pages 1-15, March.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:12:y:2019:i:8:p:1561-:d:225668. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.