IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v12y2019i8p1411-d222194.html
   My bibliography  Save this article

A Study on Ceiling Temperature Distribution and Critical Exhaust Volumetric Flow Rate in a Long-Distance Subway Tunnel Fire with a Two-Point Extraction Ventilation System

Author

Listed:
  • Peng Zhao

    (School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, China)

  • Zhongyuan Yuan

    (School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, China)

  • Yanping Yuan

    (School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, China)

  • Nanyang Yu

    (School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, China)

  • Tao Yu

    (School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, China)

Abstract

Smoke control is a crucial issue in a long-distance subway tunnel fire, and a two-point extraction ventilation system is an effective way to solve this problem, due to the characteristics of controlling the smoke in a limited area and removing high-temperature and toxic smoke in time. In this study, the ceiling temperature distribution and the critical exhaust volumetric flow rate to control the smoke in the zone between two extraction vents were investigated in a long-distance subway tunnel fire with a two-point extraction ventilation system. Experiments were carried out in a 1/20 reduced-scale tunnel model based on Froude modeling. Factors, including the heat release rate (HRR), the extraction vent length, the internal distance between two extraction vents and exhaust volumetric flow rate, were studied. Smoke temperature below the ceiling, exhaust volumetric flow rate and smoke spreading configurations were measured. The ceiling temperature distribution was analyzed. Meanwhile, an empirical equation was developed to predict the critical exhaust volumetric flow rate based on the one-dimensional theory, experimental phenomenon and the analysis of forces acting at the smoke underneath the extraction vent. The coefficients in the empirical equation were determined by experimental data. Compared with the experimental results, the developed empirical equation can predict the critical exhaust volumetric flow rate well. Research outcomes in this study will be beneficial to the design and application of two-point extraction ventilation system for a long-distance subway tunnel fire.

Suggested Citation

  • Peng Zhao & Zhongyuan Yuan & Yanping Yuan & Nanyang Yu & Tao Yu, 2019. "A Study on Ceiling Temperature Distribution and Critical Exhaust Volumetric Flow Rate in a Long-Distance Subway Tunnel Fire with a Two-Point Extraction Ventilation System," Energies, MDPI, vol. 12(8), pages 1-18, April.
  • Handle: RePEc:gam:jeners:v:12:y:2019:i:8:p:1411-:d:222194
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/12/8/1411/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/12/8/1411/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Bei Cao & Xiaodong Zhou & Yubiao Huang & Yuan Zheng & Kai Ye & Hong Liu & Lizhong Yang, 2020. "An Experimental Investigation of the External Wind Effects on the Ceiling Temperature Distribution of Fire-Induced Thermal Flow in a Corridor Connected to a Compartment," Energies, MDPI, vol. 13(7), pages 1-18, April.
    2. Mateusz Zimny & Piotr Antosiewicz & Grzegorz Krajewski & Tomasz Burdzy & Adam Krasuski & Wojciech Węgrzyński, 2019. "Several Problems with Froude-Number Based Scale Modeling of Fires in Small Compartments," Energies, MDPI, vol. 12(19), pages 1-20, September.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:12:y:2019:i:8:p:1411-:d:222194. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.