Author
Listed:
- Irene Muñoz-Benavente
(Department of Electrical Engineering, Universidad Politécnica de Cartagena, 30202 Cartagena, Spain
These authors contributed equally to this work.)
- Emilio Gómez-Lázaro
(Renewable Energy Research Institute and DIEEAC/EDII-AB, Universidad de Castilla-La Mancha, 02071 Albacete, Spain
These authors contributed equally to this work.)
- Tania García-Sánchez
(Renewable Energy Research Institute and DIEEAC/EDII-AB, Universidad de Castilla-La Mancha, 02071 Albacete, Spain
These authors contributed equally to this work.)
- Antonio Vigueras-Rodríguez
(Department of Civil Engineering, Universidad Politécnica de Cartagena, 30202 Cartagena, Spain
These authors contributed equally to this work.)
- Angel Molina-García
(Department of Electrical Engineering, Universidad Politécnica de Cartagena, 30202 Cartagena, Spain
These authors contributed equally to this work.)
Abstract
This paper describes and assesses a decentralized solution based on a wireless sensor-actuator network to provide primary frequency control from demand response in power systems with high wind energy penetration and, subsequently, with relevant frequency excursions. The proposed system is able to modify the electrical power demand of a variety of thermostatically-controlled loads, maintaining minimum comfort levels and minimizing both infrastructure requirements and primary reserves from the supply side. This low-cost hardware solution avoids any additional wiring, extending the wireless sensor-actuator network technology towards small customers, which account for over a 30% share of the current power demand. Frequency excursions are collected by each individual load controller, considering not only the magnitude of the frequency deviation, but also their evolution over time. Based on these time-frequency excursion characteristics, controllers are capable of modifying the power consumption of thermostatically-controlled loads by switching them off and on, thus contributing to primary frequency control in power systems with higher generation unit oscillations as a consequence of relevant wind power integration. Field tests have been carried out in a laboratory environment to assess the load controller performance, as well as to evaluate the electrical and thermal response of individual loads under frequency deviations. These frequency deviations are estimated from power systems with a high penetration of wind energy, which are more sensitive to frequency oscillations and where demand response can significantly contribute to mitigate these frequency excursions. The results, also included in the paper, evaluate the suitability of the proposed load controllers and their suitability to decrease frequency excursions from the demand side in a decentralized manner.
Suggested Citation
Irene Muñoz-Benavente & Emilio Gómez-Lázaro & Tania García-Sánchez & Antonio Vigueras-Rodríguez & Angel Molina-García, 2017.
"Implementation and Assessment of a Decentralized Load Frequency Control: Application to Power Systems with High Wind Energy Penetration,"
Energies, MDPI, vol. 10(2), pages 1-17, January.
Handle:
RePEc:gam:jeners:v:10:y:2017:i:2:p:151-:d:88627
Download full text from publisher
Most related items
These are the items that most often cite the same works as this one and are cited by the same works as this one.
- Jinchao Li & Tianzhi Li & Liu Han, 2018.
"Research on the Evaluation Model of a Smart Grid Development Level Based on Differentiation of Development Demand,"
Sustainability, MDPI, vol. 10(11), pages 1-25, November.
- Qi Wang & Yi Tang & Feng Li & Mengya Li & Yang Li & Ming Ni, 2016.
"Coordinated Scheme of Under-Frequency Load Shedding with Intelligent Appliances in a Cyber Physical Power System,"
Energies, MDPI, vol. 9(8), pages 1-14, August.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:10:y:2017:i:2:p:151-:d:88627. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.