Author
Listed:
- Chunfeng Zhang
(College of Mechanical and Electronic Engineering, Northwest A&F University, Yangling 712100, China
Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China
Beijing PAIDE Science and Technology Development Co., Ltd., Beijing 100097, China)
- Changyuan Zhai
(Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China
College of Agricultural Engineering, Jiangsu University, Zhenjiang 212013, China)
- Meng Zhang
(Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China
College of Agricultural Engineering, Jiangsu University, Zhenjiang 212013, China)
- Chi Zhang
(Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China)
- Wei Zou
(Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China
Beijing PAIDE Science and Technology Development Co., Ltd., Beijing 100097, China)
- Chunjiang Zhao
(College of Mechanical and Electronic Engineering, Northwest A&F University, Yangling 712100, China
Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China
College of Agricultural Engineering, Jiangsu University, Zhenjiang 212013, China)
Abstract
The pulse-width modulation (PWM) variable spray system is the most widely used variable spray system in the world at present, which has the characteristics of a fast response, large flow adjustment range, and good atomization. Recently, the pressure fluctuation and droplet deposition uniformity of the PWM variable spray system caused by the intermittent spray mode of the nozzle have attracted more and more attention. In this study, a method for eliminating the inhomogeneity of ground deposition in low-frequency PWM variable sprays based on a staggered-phase drive mode was proposed, and a PWM variable spray system was built. The experimental results indicated that the pressure fluctuation amplitude upstream of the nozzle of the PWM variable spray system with the staggered-phase drive was reduced by 40.91%, and the dispersion rate of the pressure fluctuation was reduced by 62.78% (the initial pressure was 0.3 MPa, solenoid valve frequency was 5 Hz, and duty cycle was 50%). The PWM control parameters had a significant effect on the upstream pressure fluctuation (initial pressure > duty cycle > frequency). The droplet spectrum relative span of the staggered phased PWM variable spray system decreased by 24.83%, the coefficient of variation of the droplet particle size decreased by 4.40%, the particle size was more uniform, and the atomization effect was improved. The average deposition of droplets in the forward direction driven by the staggered phase was 4.87% greater than that in the same phase, and the variation rate decreased by 20.87%. The average deposition amount increased, and the deposition became more uniform. Staggered-phase spray control could effectively reduce the inhomogeneity of deposition in low-frequency PWM intermittent spraying. This research provides strong technical support for a precision variable spraying effect and droplet drift prevention.
Suggested Citation
Chunfeng Zhang & Changyuan Zhai & Meng Zhang & Chi Zhang & Wei Zou & Chunjiang Zhao, 2024.
"Staggered-Phase Spray Control: A Method for Eliminating the Inhomogeneity of Deposition in Low-Frequency Pulse-Width Modulation (PWM) Variable Spray,"
Agriculture, MDPI, vol. 14(3), pages 1-21, March.
Handle:
RePEc:gam:jagris:v:14:y:2024:i:3:p:465-:d:1356145
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jagris:v:14:y:2024:i:3:p:465-:d:1356145. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.