Thermal comfort temperature range for factory workers in warm humid tropical climates

Author

Listed:
  • Wijewardane, S.
  • Jayasinghe, M.T.R.

Abstract

The ability to operate factory buildings as free running will be very useful in the context of saving energy needed for providing adequate thermal comfort for workers in warm humid tropical climatic conditions. The upper limits of thermally comfortable temperatures were established with comfort surveys carried out in three factory buildings without much ventilation. The surveys were then repeated to determine the effects of ventilation as well. The comfort surveys indicated that workers acclimatized to warm humid climatic condition could tolerate up to 30°C without much ventilation when engaged in light factory work. This comfort temperature limit can be increased up to 34°C when indoor air velocities are maintained as high as 0.6ms−1. It is also shown that these studies validate the earlier predictions of adaptive models for warm humid climates. The ability of workers to tolerate elevated temperatures could be used to highlight some concepts that can be considered in the planning of large-scale industrial parks, so that factories could be operated with minimum energy allocated for providing thermal comfort.

Suggested Citation

  • Wijewardane, S. & Jayasinghe, M.T.R., 2008. "Thermal comfort temperature range for factory workers in warm humid tropical climates," Renewable Energy, Elsevier, vol. 33(9), pages 2057-2063.
  • Handle: RePEc:eee:renene:v:33:y:2008:i:9:p:2057-2063
    DOI: 10.1016/j.renene.2007.11.009
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0960148107003783
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.renene.2007.11.009?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Abro, Riazuddin S., 1994. "Recognition of passive cooling techniques," Renewable Energy, Elsevier, vol. 5(5), pages 1143-1146.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Ahmad, Irshad, 2010. "Performance of antisolar insulated roof system," Renewable Energy, Elsevier, vol. 35(1), pages 36-41.
    2. Calautit, John Kaiser & Hughes, Ben Richard & O’Connor, Dominic & Shahzad, Sally Salome, 2017. "Numerical and experimental analysis of a multi-directional wind tower integrated with vertically-arranged heat transfer devices (VHTD)," Applied Energy, Elsevier, vol. 185(P2), pages 1120-1135.
    3. Abolfazl Heidari & Sadra Sahebzadeh & Zahra Dalvand, 2017. "Natural Ventilation in Vernacular Architecture of Sistan, Iran; Classification and CFD Study of Compound Rooms," Sustainability, MDPI, vol. 9(6), pages 1-19, June.
    4. Beilei Qin & Xi Xu & Takashi Asawa & Lulu Zhang, 2022. "Experimental and Numerical Analysis on Effect of Passive Cooling Methods on an Indoor Thermal Environment Having Floor-Level Windows," Sustainability, MDPI, vol. 14(13), pages 1-24, June.
    5. Calautit, John Kaiser & Hughes, Ben Richard & Shahzad, Sally Salome, 2015. "CFD and wind tunnel study of the performance of a uni-directional wind catcher with heat transfer devices," Renewable Energy, Elsevier, vol. 83(C), pages 85-99.
    6. Artem Holstov & Graham Farmer & Ben Bridgens, 2017. "Sustainable Materialisation of Responsive Architecture," Sustainability, MDPI, vol. 9(3), pages 1-20, March.
    7. Sadra Sahebzadeh & Abolfazl Heidari & Hamed Kamelnia & Abolfazl Baghbani, 2017. "Sustainability Features of Iran’s Vernacular Architecture: A Comparative Study between the Architecture of Hot–Arid and Hot–Arid–Windy Regions," Sustainability, MDPI, vol. 9(5), pages 1-28, May.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:33:y:2008:i:9:p:2057-2063. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.