IDEAS home Printed from https://ideas.repec.org/a/zib/zbnasm/v6y2022i2p28-33.html
   My bibliography  Save this article

Evaluation Of Patient Absorbed Dose Of Conventional X-Rays Using Direct Method In Some Hospitals In Port Harcourt, Nigeria

Author

Listed:
  • Etim

    (Department of Physics, Akwa Ibom State University, Mkpat Ennin, Akwa Ibom State, Nigeria.)

  • Akanimo Edem

    (Department of Physics, Akwa Ibom State University, Mkpat Ennin, Akwa Ibom State, Nigeria)

  • Akpan

    (Department of Physics, Akwa Ibom State University, Mkpat Ennin, Akwa Ibom State, Nigeria)

  • Ita Okon

    (Department of Physics, Akwa Ibom State University, Mkpat Ennin, Akwa Ibom State, Nigeria)

  • Yawo

    (Department of Physics, Akwa Ibom State University, Mkpat Ennin, Akwa Ibom State, Nigeria)

  • Okwet Joseph

    (Department of Physics, Akwa Ibom State University, Mkpat Ennin, Akwa Ibom State, Nigeria)

Abstract

In this work, entrance skin dose was used to evaluate patient absorption dose of conventional X-rays using a direct method in some hospitals in Port-Harcourt, Rivers State. The method was based on the guidelines established by the NBIRR protocols. Questionnaires were distributed to two (2) X-ray facilities in Port Harcourt, Rivers State with code names GHC and UPTH in order to obtain information about X-ray machines such as type, model, waveform, filtration, etc., and radiological parameters used during two common diagnostic procedures such as Kilo Peak Voltage (kVp) and Milli Ampere Times Seconds (mAs). The two types of X-ray exams considered were chest (PA) and abdomen (AP). The weight and height of each patient totaling one hundred (100) were measured and two TLD badges were used on each patient to record the patient’s dose while a TLD reader (Harshaw 6600) was used to read the chips and an oven (annealing machine) was also used to anneal the chips. Mean ESD (mGy) was estimated and compared with International Established Reference Values. It was found that the mean ESD (mGy) for chest (PA) was 1.40, which is higher than the standard values of 0.17, 0.40, and 0.30 for USA, IAEA, and NRP, respectively. While the mean ESD (mGy) for the abdomen (AP) was found to be 1.62, which was higher than the standard values of 0.56, 1.02, and 102 for the USA, IAEA, and NRP, respectively. Generally, it was observed that there was a wide variation in patient dose for the two different types of x-ray examinations, which could be attributed to several factors, such as the type of x-ray machine used, radiographic techniques.

Suggested Citation

  • Etim & Akanimo Edem & Akpan & Ita Okon & Yawo & Okwet Joseph, 2022. "Evaluation Of Patient Absorbed Dose Of Conventional X-Rays Using Direct Method In Some Hospitals In Port Harcourt, Nigeria," Acta Scientifica Malaysia (ASM), Zibeline International Publishing, vol. 6(2), pages 28-33, May.
  • Handle: RePEc:zib:zbnasm:v:6:y:2022:i:2:p:28-33
    DOI: 10.26480/asm.02.2022.28.33
    as

    Download full text from publisher

    File URL: https://actascientificamalaysia.com/archives/ASM/2asm2022/2asm2022-28-33.pdf
    Download Restriction: no

    File URL: https://libkey.io/10.26480/asm.02.2022.28.33?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:zib:zbnasm:v:6:y:2022:i:2:p:28-33. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Zibeline International Publishing (email available below). General contact details of provider: https://actascientificamalaysia.com/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.