Author
Listed:
- Muhammed Mufazzal Hossen
(Nuclear Power and Energy Division, Bangladesh Atomic Energy Commission, E-12/A Agargaon, Sher-e-Bangla Nagar, Dhaka-1207, Bangladesh)
- Saikat Ahmed, Mahmud Hossain
(Nuclear Power and Energy Division, Bangladesh Atomic Energy Commission, E-12/A Agargaon, Sher-e-Bangla Nagar, Dhaka-1207, Bangladesh)
Abstract
The loss of coolant accident (LOCA) in the cold leg, including breaks of 0.000507 m2 (Case-1), a break of 0.008110 m2 (Case-2), a break of 0.129720 m2 (Case-3), a break of 0.164170 m2 (Case-4), 0.202680 m2 (Case-5), and a break of 0.240800 m2 (Case-6), with the concurrent incident of the anticipated transient without scram (ATWS) and the loss of AC power, have been simulated and analyzed by applying the personal computer transient analyzer (PCTRAN) simulator model of the VVER-1200 nuclear power plant (NPP). The larger break size results in a smaller pressure and temperature of the reactor coolant system (RCS) during the simulation period. The RCS pressure was lower than 110% of the initial operating pressure in all cases. The secondary side pressure of the steam generator was stabilized earlier for the larger break accident cases. There is no decrease in the liquid level of the core in Cases 1 and 2, but it becomes empty in Cases 3, 4, 5, and 6 just after the initiation of the accident. The pressurizer liquid level increases rapidly for Cases 1 and 2, due to the liquid surge towards the pressurizer after the initiation of the accident, but it becomes empty in Cases 3, 4, 5, and 6. The falling liquid level of the steam generator is higher in smaller break accident cases. The break mass flow rate decreases to a plateau value earlier for smaller break cases. The thermal power of the reactor, peak cladding temperature (PCT), and fuel temperature showed a rapid drop after the initiation of the accident, followed by an increase to a peak value. At the end of the simulation, there was a drastic drop in reactor thermal power, PCT, and fuel temperatures for Case-6 due to the supply of boric acid solution to the reactor. Among the accident cases, the maximum values of PCT and peak fuel temperature for Case-6 were recorded as 646.20 °C and 2084.88 °C, respectively, which is within the acceptable range for a design basis accident of a pressurized water reactor. Thus, the major thermal-hydraulic parameters were within acceptable values for the cold leg break LOCA with the simultaneous initiation of the ATWS and the loss of AC power of the VVER-1200 NPP model of the PCTRAN simulator.
Suggested Citation
Muhammed Mufazzal Hossen & Saikat Ahmed, Mahmud Hossain, 2024.
"Analyzing Thermal-Hydraulic Parameters During Cold Leg Loss Of Coolant Accident Without Reactor Scram Using Pctran Model Of Vver-1200,"
Acta Mechanica Malaysia (AMM), Zibeline International Publishing, vol. 7(1), pages 16-22, January.
Handle:
RePEc:zib:zbnamm:v:7:y:2024:i:1:p:16-22
DOI: 10.26480/amm.01.2024.16.22
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:zib:zbnamm:v:7:y:2024:i:1:p:16-22. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Zibeline International Publishing The email address of this maintainer does not seem to be valid anymore. Please ask Zibeline International Publishing to update the entry or send us the correct address
(email available below). General contact details of provider: https://actamechanicamalaysia.com/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.