Author
Listed:
- ZHUOQING YANG
(Research Center for Ubiquitous MEMS and Micro Engineering (UMEMSME), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8564, Japan;
Science and Technology on Micro/Nano Fabrication Laboratory, Shanghai Jiao Tong University, Shanghai, 200240, P. R. China)
- YI ZHANG
(Research Center for Ubiquitous MEMS and Micro Engineering (UMEMSME), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8564, Japan)
- TOSHIHIRO ITOH
(Research Center for Ubiquitous MEMS and Micro Engineering (UMEMSME), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8564, Japan)
- RYUTARO MAEDA
(Research Center for Ubiquitous MEMS and Micro Engineering (UMEMSME), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8564, Japan)
Abstract
In this present paper, a three-electrode system has been fabricated and integrated on the cylindrical polymer capillary surface by micromachining technology, which could be used as a flexible and implantable microneedle for glucose sensor application in future. A UV lithography system is successfully developed for high resolution alignment on cylindrical substrates. The multilayer alignment exposure for cylindrical polymer capillary substrate is for the first time realized utilizing the lithography system. The ±1 μm alignment precision has been realized on the 330 μm-outer diameter polymer capillary surface, on which the three-electrode structure consisting of two platinum electrodes and oneAg/AgClreference electrode has been fabricated. The fabricated whole device as microneedle for glucose sensor application has been also characterized in 1 mol/LKCland 0.02 mol/LK3Fe(CN)6mix solution. The measured cyclic voltammetry curve shows that the prepared three-electrode system has a good redox property.
Suggested Citation
Zhuoqing Yang & Yi Zhang & Toshihiro Itoh & Ryutaro Maeda, 2013.
"New Fabrication Method Of Three-Electrode System On Cylindrical Capillary Surface As A Flexible Implantable Microneedle,"
Surface Review and Letters (SRL), World Scientific Publishing Co. Pte. Ltd., vol. 20(03n04), pages 1-8.
Handle:
RePEc:wsi:srlxxx:v:20:y:2013:i:03n04:n:s0218625x13500273
DOI: 10.1142/S0218625X13500273
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:wsi:srlxxx:v:20:y:2013:i:03n04:n:s0218625x13500273. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Tai Tone Lim (email available below). General contact details of provider: http://www.worldscinet.com/srl/srl.shtml .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.