Author
Listed:
- KENYA SHIMADA
(Hiroshima Synchrotron Radiation Center, Hiroshima University, Higashi-Hiroshima 739-8526, Japan)
- MASASHI ARITA
(Hiroshima Synchrotron Radiation Center, Hiroshima University, Higashi-Hiroshima 739-8526, Japan)
- YUKIHARU TAKEDA
(Graduate School of Science, Hiroshima University, Higashi-Hiroshima 739-8526, Japan)
- HIROYUKI FUJINO
(Graduate School of Science, Hiroshima University, Higashi-Hiroshima 739-8526, Japan)
- KENICHI KOBAYASHI
(Hiroshima Synchrotron Radiation Center, Hiroshima University, Higashi-Hiroshima 739-8526, Japan)
- TAKAMASA NARIMURA
(Graduate School of Science, Hiroshima University, Higashi-Hiroshima 739-8526, Japan)
- HIROFUMI NAMATAME
(Hiroshima Synchrotron Radiation Center, Hiroshima University, Higashi-Hiroshima 739-8526, Japan)
- MASAKI TANIGUCHI
(Hiroshima Synchrotron Radiation Center, Hiroshima University, Higashi-Hiroshima 739-8526, Japan;
Graduate School of Science, Hiroshima University, Higashi-Hiroshima 739-8526, Japan)
Abstract
In order to study the electronic states of solids, using high-resolution, low-temperature photoemission spectroscopy (PES) with tunable photon energies, we have constructed a high-resolution undulator beamline operating in the photon-energy range 26–300 eV at the compact 700 MeV electron-storage ring HiSOR located at Hiroshima University. By way of gas-phase experiments, with photon flux larger than2 × 1010photons/s, photon-energy resolving powers ofE/ΔE > 16000and 3800 were obtained athν ~ 48eV and ~ 244 eV, respectively. High-resolution PES experiments on evaporated Au at 8 K were performed at the beamline with a total energy resolution ofΔE = 12meV athν = 48eV. Among the first experiments from the beamline, a resonant photoemission study of UNiSn is presented. The U 5f derived peak is significantly enhanced athν = 98eV.
Suggested Citation
Kenya Shimada & Masashi Arita & Yukiharu Takeda & Hiroyuki Fujino & Kenichi Kobayashi & Takamasa Narimura & Hirofumi Namatame & Masaki Taniguchi, 2002.
"High-Resolution, Low-Temperature Photoemission Spectroscopy At The Hisor Linear Undulator Beamline,"
Surface Review and Letters (SRL), World Scientific Publishing Co. Pte. Ltd., vol. 9(01), pages 529-534.
Handle:
RePEc:wsi:srlxxx:v:09:y:2002:i:01:n:s0218625x02002592
DOI: 10.1142/S0218625X02002592
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:wsi:srlxxx:v:09:y:2002:i:01:n:s0218625x02002592. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Tai Tone Lim (email available below). General contact details of provider: http://www.worldscinet.com/srl/srl.shtml .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.