Abstract
Aims and objectives To confirm the accuracy of the EASI system compared to the standard 12‐lead electrocardiogram, which is the gold standard, in monitoring the two major parameters used in the Coronary Care Units to detect myocardial ischaemia: ST‐segment and J‐point. Background Continuous electrocardiograph monitoring is used in the Coronary Care Units to detect cardiac conduction abnormalities and to show the morphology of electrocardiographic waves and tracts. Its accuracy is essential for efficient nursing vigilance, particularly for monitoring the ST segment and the J‐point, in which alterations may indicate the onset of myocardial ischaemia. Design An observational study was conducted. Methods The enrolled patients (n = 253) simultaneously underwent standard electrocardiogram (10 electrodes) and EASI electrocardiogram (five electrodes). Data were collected by the Coronary Care Units nurses. Tests to compare differences in means and medians between the two sets of measurements were performed, and the Bland‐Altman plots were used to illustrate their agreement. Results All 6·072 electrocardiographic leads (3·036 standard and 3·036 EASI) were recorded and analysed. Between the two measurement methods, very small statistically significant differences were found in some leads which are not clinically relevant for both the ST‐segment or the J‐point. Conclusions This study confirms that the accuracy of the EASI 12‐leadelectrocardiogram, compared to the standard 12‐leadelectrocardiogram, which is the gold standard, is acceptable for clinical practice to monitor the two major parameters used in the Coronary Care Units for detecting myocardial ischaemia: ST‐segment and J‐point. Relevance to clinical practice The EASI system ensures: (1) ease of use and comfort for patients admitted to Coronary Care Units because it only requires five electrodes; (2) increased efficacy of nursing vigilance in the early detection of changes in ST‐segment and J‐ point measurements.
Suggested Citation
Lancia Loreto & Toccaceli Andrea & Dignani Lucia & Lucertini Carla & Petrucci Cristina & Romano Silvio, 2016.
"Accuracy of EASI 12‐lead ECGs in monitoring ST‐segment and J‐point by nurses in the Coronary Care Units,"
Journal of Clinical Nursing, John Wiley & Sons, vol. 25(9-10), pages 1282-1291, May.
Handle:
RePEc:wly:jocnur:v:25:y:2016:i:9-10:p:1282-1291
DOI: 10.1111/jocn.13168
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:wly:jocnur:v:25:y:2016:i:9-10:p:1282-1291. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Wiley Content Delivery (email available below). General contact details of provider: https://doi.org/10.1111/(ISSN)1365-2702 .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.