- Martinka Jozef
(Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety Ulica Jána Bottu 2781/25, 917 24Trnava, Slovak Republic)
- Rantuch Peter
(Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety Ulica Jána Bottu 2781/25, 917 24Trnava, Slovak Republic)
- Wachter Igor
(Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety Ulica Jána Bottu 2781/25, 917 24Trnava, Slovak Republic)
- Balog Karol
(Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety Ulica Jána Bottu 2781/25, 917 24Trnava, Slovak Republic)
Abstract
This paper deals with the fire risk of a selected halogen-free electrical cable. The research was objected to a three-core power electric cable for a fixed installation CHKE J3x1.5 (cross section of each copper core was 1.5 mm2) with a declared class of reaction to fire B2ca, s1, d1, a1. The electrical cable was manufactured and supplied by VUKI, a. s., Slovakia. The fire risk of the electric cable was evaluated based on the heat release rate, total heat release, smoke release rate, total smoke release and effective heat of combustion. These parameters were measured using a cone calorimeter at 50 kW m−2 (specimens and cone emitter were placed horizontally during the test). The measured electrical cable showed a maximum heat release rate of nearly 150 kW m−2, a maximum average heat emission rate of almost 100 kW m−2, a total heat release of almost 130 MJ m−2, a maximum smoke release rate of almost 2.5 s−1, a total smoke release of more than 800 m2 m−2, an effective heat of combustion (cable as a whole) of nearly 9 MJ kg−1 and an effective heat of emission (polymeric parts of the cable) of 26.5 MJ kg−1.
Suggested Citation
Martinka Jozef & Rantuch Peter & Wachter Igor & Balog Karol, 2018.
"Fire Risk of Halogen-Free Electrical Cable,"
Research Papers Faculty of Materials Science and Technology Slovak University of Technology, Sciendo, vol. 26(42), pages 21-27, June.
Handle:
RePEc:vrs:repfms:v:26:y:2018:i:42:p:21-27:n:2
DOI: 10.2478/rput-2018-0002
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:vrs:repfms:v:26:y:2018:i:42:p:21-27:n:2. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Peter Golla (email available below). General contact details of provider: https://www.sciendo.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.