IDEAS home Printed from https://ideas.repec.org/a/tuk/qipqip/v19y2015i12.html
   My bibliography  Save this article

Dimensional Verification And Quality Control Of Implants Produced By Additive Manufacturing

Author

Listed:
  • Teodor Toth
  • Radovan Hudak
  • Jozef Zivcak

Abstract

Purpose: Development of computer technology and alternative manufacturing methods in form of additive manufacturing leads to the manufacture of products with complex shapes. In the field of medicine they include, inter alia, custom-made implants manufactured for a particular patient, such as cranial implants, maxillofacial implants, etc. With regard to the fact that such implants are inserted into a patient’s body, it is necessary to perform the verification, including the shape and dimensional verification. The article deals with the application of the industrial computer tomography within the process of inspection and verification of selected custom-made implant types. Methodology/Approach: The Department of Biomedical Engineering and Measurement performs the verification of medicinal products manufactured by the additive manufacturing technologies from the Ti-6Al-4V (Grade 5) titanium alloy, using the coordinate measuring machine Carl Zeiss Contura G2 and the industrial computed tomography machine Carl Zeiss Metrotom 1500. These equipment fulfil the requirements for the identification and evaluation of dimensions of both, the external and the internal structures.Findings: The article presents the possibilities of the computed tomography utilisation in the inspection of individual implant manufacture using the additive manufacturing technologies. The results indicate that with the adjustment of appropriate input parameters (alignment), this technology is appropriate for the analysis of shape deviations, when compared with the CAD model.Research Limitation/implication: With the increasing distance of measured object from X-ray source, the machine’s resolution function decreases. Decreasing of resolution has a minor impact on the measured dimensions (relatively high tolerances), but has a significant impact on the evaluation of porosity and inclusions. Originality/Value of paper: Currently, the verification of a manufactured implant can be carried out using 3D scanners and the industrial computed tomography. The use of 3D scanners is appropriate for the shape inspection, for example the shape of an implant’s outer surface. The computed tomography is the only method for evaluation of shape deviations, defectoscopy and dimensional analysis in one measurement.

Suggested Citation

  • Teodor Toth & Radovan Hudak & Jozef Zivcak, 2015. "Dimensional Verification And Quality Control Of Implants Produced By Additive Manufacturing," Quality Innovation Prosperity, Technical University of Košice, Department of integrated management, vol. 19(1).
  • Handle: RePEc:tuk:qipqip:v:19:y:2015:i:1:2
    as

    Download full text from publisher

    File URL: http://www.qip-journal.eu/index.php/QIP/article/view/393/524
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    individual implants; measurement; additive manufacturing; actual-nominal comparison; defectoscopy;
    All these keywords.

    JEL classification:

    • Z - Other Special Topics

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:tuk:qipqip:v:19:y:2015:i:1:2. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Peter Bober (email available below). General contact details of provider: .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.