Author
Listed:
- Muhammad Imran
- Jinsheng Sun
- Xuelong Hu
- Fatima Sehar Zaidi
- Anan Tang
Abstract
Traditional process monitoring control charts (CCs) focused on sampling methods using fixed sampling intervals ( $ \mathrm {FSI} $ FSIs). The variable sampling intervals ( $ \mathrm {VSI} $ VSIs) scheme is receiving increasing attention, in which the sampling interval ( $ \mathrm {SI} $ SI) length varies according to the process monitoring statistics. A shorter $ \mathrm {SI} $ SI is considered when the process quality indicates the possibility of an out-of-control (OOC) situation; otherwise, a longer $ \mathrm {SI} $ SI is preferred. The $ \mathrm {VSI} $ VSI multivariate exponentially moving average for compositional data ( $ \mathrm {VSI} $ VSI- $ \mathrm {MEWMA}\,\mathrm {CoDa} $ MEWMACoDa) CC based on a coordinate representation using isometric log-ratio ( $ \operatorname {ilr} $ ilr) transformation is proposed in this study. A methodology is proposed to obtain the optimal parameters by considering the zero-state ( $ \mathrm {ZS} $ ZS) average time to signal ( $ \mathrm {ZATS} $ ZATS) and the steady-state (SS) average time to signal ( $ \mathrm {SATS} $ SATS). The statistical performance of the proposed CC is evaluated based on a continuous-time Markov chain ( $ \mathrm {CTMC} $ CTMC) method for both cases, the $ \mathrm {ZS} $ ZS and the SS using a fixed value of in-control (IC) $ \mathrm {ATS}_0 $ ATS0. Simulation results demonstrate that the $ \mathrm {VSI} $ VSI- $ \mathrm {MEWMA}\,\mathrm {CoDa} $ MEWMACoDa CC has significantly decreased the OOC average time to signal ( $ \mathrm {ATS} $ ATS) than the $ \mathrm {FSI}\,\mathrm {MEWMA}\,\mathrm {CoDa} $ FSIMEWMACoDa CC. Moreover, it is found that the number of variables (d) has a negative impact on the $ \mathrm {ATS} $ ATS of the $ \mathrm {VSI} $ VSI- $ \mathrm {MEWMA}\,\mathrm {CoDa} $ MEWMACoDa CC, and the subgroup size (n) has a mildly positive impact on the $ \mathrm {ATS} $ ATS of the $ \mathrm {VSI} $ VSI- $ \mathrm {MEWMA}\,\mathrm {CoDa} $ MEWMACoDa CC. At the same time, the $ \mathrm {SATS} $ SATS of the $ \mathrm {VSI} $ VSI- $ \mathrm {MEWMA}\,\mathrm {CoDa} $ MEWMACoDa CC is less than the $ \mathrm {ZATS} $ ZATS of the $ \mathrm {VSI} $ VSI- $ \mathrm {MEWMA}\,\mathrm {CoDa} $ MEWMACoDa CC for all the values of n and d. The proposed $ \mathrm {VSI} $ VSI- $ \mathrm {MEWMA}\,\mathrm {CoDa} $ MEWMACoDa CC under steady-State performs effectively compared to its competitors, such as the $ \mathrm {FSI} $ FSI- $ \mathrm {MEWMA}\,\mathrm {CoDa} $ MEWMACoDa CC, the $ \mathrm {VSI} $ VSI- $ T^2\,\mathrm {CoDa} $ T2CoDa CC and the $ \mathrm {FSI} $ FSI- $ T^2\,\mathrm {CoDa} $ T2CoDa CC. An example of an industrial problem from a plant in Europe is also given to study the statistical significance of the $ \mathrm {VSI} $ VSI- $ \mathrm {MEWMA}\,\mathrm {CoDa} $ MEWMACoDa CC.
Suggested Citation
Muhammad Imran & Jinsheng Sun & Xuelong Hu & Fatima Sehar Zaidi & Anan Tang, 2024.
"Investigating zero-state and steady-state performance of MEWMA-CoDa control chart using variable sampling interval,"
Journal of Applied Statistics, Taylor & Francis Journals, vol. 51(5), pages 913-934, April.
Handle:
RePEc:taf:japsta:v:51:y:2024:i:5:p:913-934
DOI: 10.1080/02664763.2023.2170336
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:japsta:v:51:y:2024:i:5:p:913-934. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/CJAS20 .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.