Abstract
Problems, such as broken screws, broken rods, and cage subsidence after clinical spinal fusion surgery affect the success rate of fusion surgery and the fixation effect of fusion segments, and these problems still affect the treatment and postoperative recovery of patients. In this study, we used the biomechanical finite element analysis method to analyze and study the fixation effect of three kinds of spinal internal fixation systems on L4–L5 lumbar spine segments in percutaneous endoscopic posterior lumbar interbody fusion (PE-PLIF). The three different fixation systems compared in this study include bilateral pedicle screw fixation (M1); bilateral pedicle screw with cross-link fixation (M2); bilateral pedicle screws with double bent rods fixation (M3). The internal fixation systems with different structures were analyzed with the help of Hypermesh, and Abaqus. It was found that the internal fixation system with double bent rods reduced screw stresses by 23.8 and 22.2% in right and left axial rotation than the traditional bilateral pedicle screw system, while titanium rod stresses were reduced by 9.6, 3.7, 9.6, and 2.9% in flexion, left and right lateral bending, and right axial rotation, respectively, and L5 upper endplate stresses were reduced by 35.5, 18.9, 38.4, 10.2, and 48.3% in flexion, left and right lateral bending, and left and right axial rotation, respectively. The spinal range of motion (ROM) of the M3 internal fixation system was less than that of the M1 and M2 internal fixation systems in left lateral bending, left lateral rotation, and right axial rotation, and the intact vertebral ROM was reduced by 93.7, 94.9, and 90.9%, respectively. The double bent rod structure of the spinal internal fixation system has better biomechanical properties, which can effectively reduce the risk of screw breakage, loosening, cage subsidence, and endplate collapse after fusion surgery.
Suggested Citation
Lei Ma & Yang Yan & Xiyu Wang & Songyuan Wang & Feng Li & Kai Zhang & Xuanze Fan & Hao Zhong & Xinqi Lou & Xiaogang Wu & Yanru Xue & Yanqin Wang & Liming He & Ruizhong Yan & Weiyi Chen, 2024.
"Biomechanical evaluation and optimal design of a pedicle screw with double bent rods internal fixation system based on PE-PLIF fusion,"
Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 27(11), pages 1448-1459, August.
Handle:
RePEc:taf:gcmbxx:v:27:y:2024:i:11:p:1448-1459
DOI: 10.1080/10255842.2023.2245517
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:27:y:2024:i:11:p:1448-1459. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.