Author
Listed:
- Aleksander Leszczynski
- Frank Meyer
- Yann-Philippe Charles
- Caroline Deck
- Rémy Willinger
Abstract
Surgical corrections of degenerative lumbar scoliosis and sagittal malalignment are associated with significant complications, such as rod fractures and pseudarthrosis, particularly in the lumbosacral junction. Finite element studies can provide relevant insights to improve performance of spinal implants. The aim of the present study was to present the development of non-instrumented and instrumented Finite Element Models (FEMs) of the lumbopelvic spine and to compare numerical results with experimental data available in the literature. The lumbo-pelvic spine FEM was based on a CT-scan from an asymptomatic volunteer representing the 50th percentile male. In a first step a calibration of mechanical properties was performed in order to obtain a quantitative agreement between numerical results and experimental data for defect stages of spinal segments. Then, FEM results were compared in terms of range of motion and strains in rods to in-vitro experimental data from the literature for flexible non-instrumented and instrumented lumbar spines. Numerical results from the calibration process were consistent with experimental data, especially in flexion. A positive agreement was obtained between FEM and experimental results for the lumbar and sacroiliac segments. Instrumented FEMs predicted the same trends as experimental in-vitro studies. The instrumentation configuration consisting of double rods and an interbody cage at L5-S1 maximally reduced range of motion and strains in main rods and thus had the lowest risk of pseudarthrosis and rod fracture. The developed FEMs were found to be consistent with published experimental results; therefore they can be used for further post-operative complication investigations.
Suggested Citation
Aleksander Leszczynski & Frank Meyer & Yann-Philippe Charles & Caroline Deck & Rémy Willinger, 2022.
"Development of a flexible instrumented lumbar spine finite element model and comparison with in-vitro experiments,"
Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 25(2), pages 221-237, February.
Handle:
RePEc:taf:gcmbxx:v:25:y:2022:i:2:p:221-237
DOI: 10.1080/10255842.2021.1948021
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:25:y:2022:i:2:p:221-237. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.