Author
Listed:
- Jayanta Kumar Biswas
- Anindya Malas
- Sourav Majumdar
- Masud Rana
Abstract
Titanium alloy-based Pedicle screw-rod fusion is a very common technique to provide higher fusion regularity than other methods. In recent times, Carbon-fibre-reinforced (CFR)-PEEK rod is used to better reduce the fusion rate. Alternatively, total disc replacement (TDR) is also very common for the non-fusion treatment method for degenerative disc disease (DDD). This study aims to investigate flexibility (ROM), stability, stress condition in implant, implant adjacent bone of the implanted lumbar spine during different physiological movements and loading environments. The finite element (FE) intact model of the lumbar spine (L2-L5) with two-level pedicle screw-rod fusion at L3-L4-L5 and two-level artificial disc replacement was developed. CFR-PEEK was taken for rod for semi-rigid fusion. UHMWPE was taken as core part of the artificial disc. The FE models were simulated under 6, 8 and 10 Nm moments in left right lateral bending, flexion and extension movements. The total ROM was reduced for two-level pedicle screw fixation and increased for the artificial disc replacement model during flexion extension compared to the intact spine. The total ROM was reduced by around 54% and 25% for two-level fixation and increased by 30% and 19.5% for artificial disc replacement spine, under flexion-extension and left-right lateral bending respectively. For screw fixation, the ROM increased by 15% and 18% reduced by 4.5% and 14% for disc replacement at the adjacent segments for flexion-extension and left-right lateral bending.
Suggested Citation
Jayanta Kumar Biswas & Anindya Malas & Sourav Majumdar & Masud Rana, 2022.
"A comparative finite element analysis of artificial intervertebral disc replacement and pedicle screw fixation of the lumbar spine,"
Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 25(16), pages 1812-1820, December.
Handle:
RePEc:taf:gcmbxx:v:25:y:2022:i:16:p:1812-1820
DOI: 10.1080/10255842.2022.2039130
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:25:y:2022:i:16:p:1812-1820. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.