Author
Listed:
- Alexander Simileysky
- Maury L. Hull
Abstract
BackgroundIdentifying the center of the talocrural joint is crucial in defining the tibia’s mechanical axis, which is used in a variety of applications such as a reference for measuring alignment variables following total knee arthroplasty. The objectives of this study were to 1) describe a new method for determining the center of the talocrural joint, 2) determine the repeatability and reproducibility of the new method and two previously described methods for locating the center, 3) determine the limits of agreement between pairs of methods, and 4) determine angular differences in the coronal and sagittal planes between tibial mechanical axes generated by the different methods.MethodsThe new area centroid method identified the center of the talocrural joint as the centroid of the distal tibia’s articular surface. Previously described methods included the diagonal intersection and biplanar methods. For each method, the medial-lateral, anterior-posterior, and proximal-distal coordinates of the talocrural joint center and angular differences between tibial mechanical axes were determined in thirteen 3D full tibia bone models.ResultsFor the area centroid method, ICC values indicated excellent repeatability (0.97) and reproducibility (0.92). For the biplanar method, ICC values indicated good repeatability (0.86) and fair reproducibility (0.40). For the diagonal intersection method, ICC values indicated moderate repeatability (0.71) and fair reproducibility (0.46). Limits of agreement were tightest between the area centroid and diagonal intersection methods (± 4.1 mm). Angular differences between tibial mechanical axes were limited to 3°.ConclusionThe area centroid method locates the anatomic center of the talocrural joint, offers better repeatability and reproducibility than existing methods, and is recommended when identifying the tibial mechanical axis.
Suggested Citation
Alexander Simileysky & Maury L. Hull, 2022.
"Repeatability, reproducibility, and agreement of three methods for finding the mechanical axis of the human tibia,"
Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 25(11), pages 1301-1309, August.
Handle:
RePEc:taf:gcmbxx:v:25:y:2022:i:11:p:1301-1309
DOI: 10.1080/10255842.2021.2012166
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:25:y:2022:i:11:p:1301-1309. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .
Please note that corrections may take a couple of weeks to filter through