Author
Listed:
- Pedro Henrique Wentz Tretto
- Mateus Bertolini Fernandes dos Santos
- Aloisio Oro Spazzin
- Gabriel Kalil Rocha Pereira
- Atais Bacchi
Abstract
The aim of this study was to assess the stress/strain in dental implant/abutments with alternative materials, in implants with different microgeometry, through finite element analysis (FEA). Three-dimensional models were created to simulate the clinical situation of replacement of a maxillary central incisor with implants, in a type III bone, with a provisional single crown, loaded with 100 N in a perpendicular direction. The FEA parameters studied were: implant materials—titanium, porous titanium, titanium-zirconia, zirconia, reinforced fiberglass composite (RFC), and polyetheretherketone (PEEK); and abutment materials—titanium, zirconia, RFC, and PEEK; implant macrogeometry—tapered of trapezoidal threads (TTT) and cylindrical of triangular threads (CTT) (ø4.3 mm × 11 mm). Microstrain, von Mises, shear, and maximum and minimum principal stresses in the structures and in peri-implant bone were compared. There was increased stress and strain in peri-implant bone tissue caused by implants of materials with lower elastic modulus (mainly for PEEK and RFC). They also presented higher concentration of stresses in the implant itself (especially RFC). Zirconia implants led to lower stress and strains in peri-implant bone tissue. Less rigid abutments (RFC and PEEK) associated with titanium implants led to higher stress in the implant and in peri-implant bone tissue. The TTT macrogeometry showed a higher stress concentration in the implant and peri-implant bone tissue. The stress/strain in peri-implant bone tissue and implant structures were affected by the material used, where reduced values were caused by stiffer materials. Lower stress/strain values were obtained with cylindrical implants of triangular treads.
Suggested Citation
Pedro Henrique Wentz Tretto & Mateus Bertolini Fernandes dos Santos & Aloisio Oro Spazzin & Gabriel Kalil Rocha Pereira & Atais Bacchi, 2020.
"Assessment of stress/strain in dental implants and abutments of alternative materials compared to conventional titanium alloy—3D non-linear finite element analysis,"
Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 23(8), pages 372-383, June.
Handle:
RePEc:taf:gcmbxx:v:23:y:2020:i:8:p:372-383
DOI: 10.1080/10255842.2020.1731481
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:23:y:2020:i:8:p:372-383. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.