Author
Listed:
- Subrata Mondal
- Rajesh Ghosh
Abstract
One of the major causes of implant loosening is due to excessive bone resorption surrounding the implant due to bone remodelling. The objective of the study is to investigate the effects of implant material and implant–bone interface conditions on bone remodelling around tibia bone due to total ankle replacement. Finite element models of intact and implanted ankles were developed using CT scan data sets. Bone remodelling algorithm was used in combination with FE analysis to predict the bone density changes around the ankle joint. Dorsiflexion, neutral, and plantar flexion positions were considered, along with muscle force and ligaments. Implant–bone interfacial conditions were assumed as debonded and bonded to represent non-osseointegration and fully osseointegration at the porous coated surface of the implant. To investigate the effect of implant material, three finite element models having different material combinations of the implant were developed. For model 1, tibial and talar components were made of Co–Cr–Mo, and meniscal bearing was made of UHMWPE. For model 2, tibial and talar components were made of ceramic and meniscal bearing was made of UHMWPE. For model 3, tibial and talar components were made of ceramic and meniscal bearing was made of CFR-PEEK. Changes in implant material showed no significant changes in bone density due to bone remodelling. Therefore, ceramic appears to be a viable alternative to metal and CFR-PEEK can be used in place of UHMWPE. This study also indicates that proper bonding between implant and bone is essential for long-term survival of the prosthetic components.
Suggested Citation
Subrata Mondal & Rajesh Ghosh, 2019.
"Bone remodelling around the tibia due to total ankle replacement: effects of implant material and implant–bone interfacial conditions,"
Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 22(16), pages 1247-1257, December.
Handle:
RePEc:taf:gcmbxx:v:22:y:2019:i:16:p:1247-1257
DOI: 10.1080/10255842.2019.1661385
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:22:y:2019:i:16:p:1247-1257. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.