Author
Listed:
- Jeremie Peres
- Christophe Bastien
- Jesper Christensen
- Zahra Asgharpour
Abstract
With the increasing use of Computer Aided Engineering, it has become vital to be able to evaluate the accuracy of numerical models. Specific methods such as CORA were developed to objectively evaluate the correlation between a physical test and a numerical simulation results in terms of parameter vs time. However, no metric has so far been developed for Force Vs Deflection (FvD) signals often used in crashworthiness and biomechanics. A unique method called the Minimum Area Discrepancy Method, or MADM, is proposed to address this deficiency. This new method initially calculates a parameter ‘R’ which represents the area between numerical model and the average physical test response and then divides it by the average area generated by the upper and lower test corridors, based on the same standard deviation. The parameter ‘R’ is then normalized between 0 (no correlation) and 1 (perfect correlation) to become the MADM correlation rating. The MADM method was then validated by comparing a one dimensional Finite Element (FE) model of a chest model, under 2 impact velocities, against reference Post Mortem Human Subject (PMHS) data. The MADM method was further used to improve the correlation of this thorax model, by varying model parameters and generating 81 model variations. Based on the MADM ratings, a set parameter values leading to the best fit was identified. The best fit exhibits a response significantly better than the original chest model. MADM is novel, unique, easy to use and fulfills an important gap in objectively evaluating FVD correlation responses. AbbreviationsMADMCorrelation rating value (Minimum Area Discrepancy Method)MADMn,mMADM correlation rating using a specific scaling value of ‘n’ and power rating ‘m’FvDForce versus DisplacementFvTForce versus TimeDvTDisplacement versus TimeNMNumerical modelPEPhysical ExperimentAmodelArea under the average signal and the Numerical ModelAupperArea under the average signal +1 standard deviationAlowerArea under the average signal -1 standard deviationRRatio between Amodel and the average of Aupper and Alower
Suggested Citation
Jeremie Peres & Christophe Bastien & Jesper Christensen & Zahra Asgharpour, 2019.
"A minimum area discrepancy method (MADM) for force displacement response correlation,"
Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 22(11), pages 981-996, August.
Handle:
RePEc:taf:gcmbxx:v:22:y:2019:i:11:p:981-996
DOI: 10.1080/10255842.2019.1610745
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:22:y:2019:i:11:p:981-996. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.