Author
Abstract
Sparse geometric information from limited field-of-view medical images is often used to reconstruct the femur in biomechanical models of the hip and knee. However, the full femur geometry is needed to establish boundary conditions such as muscle attachment sites and joint axes which define the orientation of joint loads. Statistical shape models have been used to estimate the geometry of the full femur from varying amounts of sparse geometric information. However, the effect that different amounts of sparse data have on reconstruction accuracy has not been systematically assessed. In this study, we compared shape model and linear scaling reconstruction of the full femur surface from varying proportions of proximal and distal partial femur geometry in combination with morphometric and landmark data. We quantified reconstruction error in terms of surface-to-surface error as well as deviations in the reconstructed femur’s anatomical coordinate system which is important for biomechanical models. Using a partial proximal femur surface, mean shape model-based reconstruction surface error was 1.8 mm with 0.15° or less anatomic axis error, compared to 19.1 mm and 2.7–5.6° for linear scaling. Similar results were found when using a partial distal surface. However, varying amounts of proximal or distal partial surface data had a negligible effect on reconstruction accuracy. Our results show that given an appropriate set of sparse geometric data, a shape model can reconstruct full femur geometry with far greater accuracy than simple scaling.
Suggested Citation
Ju Zhang & Thor F. Besier, 2017.
"Accuracy of femur reconstruction from sparse geometric data using a statistical shape model,"
Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 20(5), pages 566-576, April.
Handle:
RePEc:taf:gcmbxx:v:20:y:2017:i:5:p:566-576
DOI: 10.1080/10255842.2016.1263301
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:20:y:2017:i:5:p:566-576. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.