Author
Listed:
- Marcel M. Rossi
- Amanda P. Silvatti
- Fabio A.S. Dias
- Ricardo M.L. Barros
Abstract
This study aimed at assessing the applicability of a robust method to determine and correct lens distortion before using the direct linear transformation (DLT) algorithm in three-dimensional motion analysis. The known length of a rigid bar was reconstructed under different conditions of working volume (interpolation or extrapolation), number of cameras (2 or 4), position of the cameras (wide or narrow angle between optical axes), camera focal distance (4 or 8 mm) and number of control points (CPs; 8, 12, 18 or 162), through four different camera set-ups. The accuracy (percent root mean square error) of Set-up 2 (non-extrapolated working volume; two cameras; 4 mm focal distance; narrow optical axes angle) decreased with less CPs (162: 0.73%; 8: 2.78%). Set-up 1 (non-extrapolated working volume; two cameras; 8 mm focal distance; wide optical axes angle), Set-up 3 (Set-ups 1 and 2 used simultaneously) and Set-up 4 (extrapolated working volume; two cameras; 4 mm focal distance; wide optical axes angle) showed minor differences in accuracy across groups of CPs, with maximum values of 0.84%, 1.20% and 1.71%, respectively. Random errors were the main source of decreased accuracy of Set-ups 2 and 4.The proposed procedure enables accurate results with no modification in the DLT-based analysis system, even with smaller calibration frames, less CPs and wide field-of-view cameras.
Suggested Citation
Marcel M. Rossi & Amanda P. Silvatti & Fabio A.S. Dias & Ricardo M.L. Barros, 2015.
"Improved accuracy in 3D analysis using DLT after lens distortion correction,"
Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 18(9), pages 993-1002, July.
Handle:
RePEc:taf:gcmbxx:v:18:y:2015:i:9:p:993-1002
DOI: 10.1080/10255842.2013.866231
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:18:y:2015:i:9:p:993-1002. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.