Author
Listed:
- Daniel Stephan
- Stephanie Panzer
- Michael Göttlinger
- Peter Augat
Abstract
Patients with calcaneus fractures experience considerable interferences with daily living activities. The quality of anatomical reconstruction is important because of its influence on functional outcome. The aim of this study was to develop an automatic algorithm based on computer tomographic (CT) images to quantify the integrity of calcaneal joint surfaces. Validation of this algorithm was done by assessing intra-individual variations of characteristic joint parameters. Bilateral hind foot CT data of 12 subjects were manually segmented, and 3D models from the calcaneus, talus and cuboid were generated. These models were implemented in a custom-made software to analyse the area, 3D orientations and bone distance of the joint surfaces of the calcaneus. Three joints were detected, and the calculated parameters were compared between right and left hind foot by the evaluation of the directional asymmetry (%DA). The results were statistically analysed with a paired t-test. The median of area (5–7 %DA) of the joint surfaces and the distance between two articulating surfaces (8–9 %DA) showed the greatest intra-individual differences. Median differences in 3D orientation were comparatively low (1–2 %DA). None of these differences was statistically significant. Inter-individual variations among subjects were several magnitudes larger than intra-individual differences. The presented computational tool provides 3D joint-specific parameters of the calcaneus, which enable to describe their respective joint integrity. The results show that only small intra-individual differences within the anatomy exist. Surgical treatment should take place with the aid of CT data from the contralateral side. Thus, a good restoration of the anatomy may be reached. The computational tool assesses the quality of reduction, and may be helpful to evaluate the outcome and quality of operative treatment based on the calculated joint-specific parameters of joint reconstructions in the hind foot.
Suggested Citation
Daniel Stephan & Stephanie Panzer & Michael Göttlinger & Peter Augat, 2014.
"Analysis of the intra-individual differences of the joint surfaces of the calcaneus,"
Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 17(15), pages 1635-1641, November.
Handle:
RePEc:taf:gcmbxx:v:17:y:2014:i:15:p:1635-1641
DOI: 10.1080/10255842.2012.759564
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:17:y:2014:i:15:p:1635-1641. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.