Author
Listed:
- F. Sassetti
- F. Guarnieri
- L. Garelli
- M. Storti
Abstract
Glaucoma drainage device (GDD) has the potential to eliminate hypotony but still suffers from poor flow control and fibrosis. The ideal shunt should change its hydraulic resistance to achieve the desired intraocular pressure (IOP). In this study, the characterisation of a preliminary design of a new GDD is presented. This is activated by means of a diaphragm, which is actuated by conducting polymers. The valve can be manufactured employing microelectromechanical system technology by soft lithography. The characterisation process is performed by numerical simulation using the finite element method, considering the coupling between the fluid and the structure (diaphragm) obtaining the hydraulic resistance for several positions of the diaphragm. To analyse the hydraulic system of the microvalve implanted in a human eye, an equivalent circuit model was used. The parameters of the equivalent circuit model were obtained from numerical simulation. The hydraulic resistance of the designed GDD varies in the range of 13.08–0.36 mmHg min/μl compared with 3.38–0.43 mmHg min/μl for the Ahmed valve. The maximum displacement of the diaphragm in the vertical direction is 18.9 μm, and the strain in the plane is 2%. The proposed preliminary design allows to control the IOP by varying the hydraulic resistance in a greater range than the existing passive valves, and the numerical simulation facilitates the characterisation and the improvement of the design before its construction, reducing time and costs.
Suggested Citation
F. Sassetti & F. Guarnieri & L. Garelli & M. Storti, 2012.
"Characterisation and simulation of an active microvalve for glaucoma,"
Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 15(12), pages 1273-1280.
Handle:
RePEc:taf:gcmbxx:v:15:y:2012:i:12:p:1273-1280
DOI: 10.1080/10255842.2011.585978
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:15:y:2012:i:12:p:1273-1280. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.