Abstract
The PleurX peritoneal drainage catheter for drainage of malignant ascites in a community setting has been evaluated by the NICE Medical Technologies Evaluation Programme. This article outlines the evidence included in the Sponsor’s submission, the independent critique by the External Assessment Centre (EAC) and the recommendations made by the Medical Technologies Advisory Committee (MTAC). In accordance with the scope issued by NICE, the intervention technology was the indwelling PleurX peritoneal catheter drainage system, the comparator was large-volume paracentesis (LVP; inpatient or outpatient) and the population was patients with treatment-resistant, recurrent malignant ascites. Nine studies (ten papers) were identified with a total of 180 PleurX-treated patients; six were case series with more than four patients that, despite being low in the hierarchy of evidence, provided useful safety information. Technical success of the initial PleurX placement procedure was 100% across five studies which reported this outcome. One study reported equal complication rates between patients treated with indwelling PleurX catheters (40 patients and 40 catheters) and those receiving repeated LVPs (67 patients and 392 procedures), 7.5% (3/40; 95% CI 1.6, 20) and 7.5% (5/67; 95% CI 2.2, 15), respectively. All remaining studies were single-arm and reported complication rates of between 0% and 59%; this wide range was largely due to variation in the definition of complications and adverse events. Using validated tools, one case series reported improvements in several ascites-related symptoms after placement of the PleurX catheter; however, an overall quality-of-life improvement at 12 weeks was not demonstrated. Positive patient opinions relating to improved symptom control and convenience were reported in a qualitative study. Cost analysis demonstrated that PleurX offered savings to the NHS when compared with repeated LVPs performed in an inpatient setting. This saving of d679 per patient was driven primarily by reducing hospital bed days (year 2009–2010 values), but would require 23.5 additional community nurse visits. Advice from clinical experts was that additional home visits were overestimated as many patients would receive such visits regardless of whether a PleurX drain had been fitted. The model demonstrated that PleurX would be more expensive than LVP procedures performed in a setting where one or less hospital bed days were used (e.g. day case or outpatient). There was uncertainty surrounding the number of patients for whom insertion of a PleurX drain would be appropriate as well as the point in the care pathway at which such treatment should be administered. MTAC supported the case for adoption and considered that the available evidence showed PleurX was clinically effective, has low complication rates, can improve quality of life and is less costly than inpatient LVP. In Medical Technology Guidance 9 (MTG9), NICE recommended that PleurX peritoneal catheter drainage system be considered for use in patients with treatment-resistant, recurrent malignant ascites. Copyright Springer International Publishing AG 2012
Suggested Citation
Judith White & Grace Carolan-Rees, 2012.
"PleurX Peritoneal Catheter Drainage System for Vacuum-Assisted Drainage of Treatment-Resistant, Recurrent Malignant Ascites,"
Applied Health Economics and Health Policy, Springer, vol. 10(5), pages 299-308, September.
Handle:
RePEc:spr:aphecp:v:10:y:2012:i:5:p:299-308
DOI: 10.1007/BF03261864
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Citations
Citations are extracted by the
CitEc Project, subscribe to its
RSS feed for this item.
Cited by:
- Iain Willits & Kim Keltie & Joyce Craig & Andrew Sims, 2014.
"WatchBP Home A for Opportunistically Detecting Atrial Fibrillation During Diagnosis and Monitoring of Hypertension: A NICE Medical Technology Guidance,"
Applied Health Economics and Health Policy, Springer, vol. 12(3), pages 255-265, June.
- Ailish Higgins & Matthew Glover & Yaling Yang & Susan Bayliss & Catherine Meads & Joanne Lord, 2014.
"EXOGEN Ultrasound Bone Healing System for Long Bone Fractures with Non-Union or Delayed Healing: A NICE Medical Technology Guidance,"
Applied Health Economics and Health Policy, Springer, vol. 12(5), pages 477-484, October.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:spr:aphecp:v:10:y:2012:i:5:p:299-308. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.springer.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.