Author
Listed:
- Xiao-Jun Li
- Yan-Cheng Ye
- Yan-Shan Zhang
- Jia-Ming Wu
Abstract
Introduction: This study presents an empirical method to model the high-energy photon beam percent depth dose (PDD) curve by using the home-generated buildup function and tail function (buildup-tail function) in radiation therapy. The modeling parameters n and μ of buildup-tail function can be used to characterize the Collimator Scatter Factor (Sc) either in a square field or in the different individual upper jaw and lower jaw setting separately for individual monitor unit check. Methods and materials: The PDD curves for four high-energy photon beams were modeled by the buildup and tail function in this study. The buildup function was a quadratic function in the form of dd2+n with the main parameter of d (depth in water) and n, while the tail function was in the form of e−μd and was composed by an exponential function with the main parameter of d and μ. The PDD was the product of buildup and tail function, PDD = dd2+n·e−μd. The PDD of four-photon energies was characterized by the buildup-tail function by adjusting the parameters n and μ. The Sc of 6 MV and 10 MV can then be expressed simply by the modeling parameters n and μ. Results: The main parameters n increases in buildup-tail function when photon energy increased. The physical meaning of the parameter n expresses the beam hardening of photon energy in PDD. The fitting results of parameters n in the buildup function are 0.17, 0.208, 0.495, 1.2 of four-photon energies, 4 MV, 6 MV, 10 MV, 18 MV, respectively. The parameter μ can be treated as attenuation coefficient in tail function and decreases when photon energy increased. The fitting results of parameters μ in the tail function are 0.065, 0.0515, 0.0458, 0.0422 of four-photon energies, 4 MV, 6 MV, 10 MV, 18 MV, respectively. The values of n and μ obtained from the fitted buildup-tail function were applied into an analytical formula of Sc = nE(S)0.63μE to get the collimator to scatter factor Sc for 6 and 10 MV photon beam, while nE, μE, S denotes n, μ at photon energy E of field size S, respectively. The calculated Sc were compared with the measured data and showed agreement at different field sizes to within ±1.5%. Conclusions: We proposed a model incorporating a two-parameter formula which can improve the fitting accuracy to be better than 1.5% maximum error for describing the PDD in different photon energies used in clinical setting. This model can be used to parameterize the Sc factors for some clinical requirements. The modeling parameters n and μ can be used to predict the Sc in either square field or individual jaws opening asymmetrically for treatment monitor unit double-check in dose calculation. The technique developed in this study can also be used for systematic or random errors in the QA program, thus improves the clinical dose computation accuracy for patient treatment.
Suggested Citation
Xiao-Jun Li & Yan-Cheng Ye & Yan-Shan Zhang & Jia-Ming Wu, 2022.
"Empirical modeling of the percent depth dose for megavoltage photon beams,"
PLOS ONE, Public Library of Science, vol. 17(1), pages 1-13, January.
Handle:
RePEc:plo:pone00:0261042
DOI: 10.1371/journal.pone.0261042
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0261042. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.