Author
Listed:
- Timothy P Szczykutowicz
- Sean D Rose
- Alexander Kitt
Abstract
Purpose: Previous efforts at increasing spatial resolution have relied on decreasing focal spot and or detector element size. Many “super resolution” methods require physical movement of a component of the imaging system. This work describes a method for achieving spatial resolution on a scale smaller than the detector pixel without motion of the object or detector. Methods: We introduce a weighting of the photon energy spectrum on a length scale smaller than a single pixel using a physical filter that can be placed between the focal spot and the object, between the object and the detector, or integrated into the x-ray source or detector. We refer to the method as sub pixel encoding (SPE). We show that if one acquires multiple measurements (i.e. x-ray projections), information can be synthesized at a spatial scale defined by the spectrum modulation, not the detector element size. Specifically, if one divides a detector pixel into n sub regions, and m photon-matter interactions are present, the number of x-ray measurements needed to solve for the detector response of each sub region is mxn. We discuss realizations of SPE using multiple x-ray spectra with an energy integrating detector, a single spectra with a photon counting detector, and the single photon-matter interaction case. We demonstrate the feasibility of the approach using a simulated energy integrating detector with a detector pitch of 2 mm for 80-140 kV medical and 200-600 kV industrial applications. Phantoms used for both example SPE realization had some features only a 1 mm detector could resolve. We calculate the covariance matrix of SPE output to characterize the and noise propagation and correlation of our test examples. Results: The mathematical foundation of SPE is provided, with details worked out for several detector types and energy ranges. Two numerical simulations were provided to demonstrate feasibility. In both the medical and industrial simulations, some phantom features were only observable with the 1 mm and SPE synthesized 2 mm detector, while the 2 mm detector was not able to visualize them. Covariance matrix analysis demonstrated negative diagonal terms for both example cases. Conclusions: The concept of encoding object information at a length scale smaller than a single pixel element, and then retrieving that information was introduced. SPE simultaneously allows for an increase in spatial resolution and provides “dual energy” like information about the underlying photon-matter interactions.
Suggested Citation
Timothy P Szczykutowicz & Sean D Rose & Alexander Kitt, 2021.
"Sub pixel resolution using spectral-spatial encoding in x-ray imaging,"
PLOS ONE, Public Library of Science, vol. 16(10), pages 1-15, October.
Handle:
RePEc:plo:pone00:0258481
DOI: 10.1371/journal.pone.0258481
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0258481. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.