IDEAS home Printed from https://ideas.repec.org/a/plo/pone00/0252777.html
   My bibliography  Save this article

Accelerating whole-heart 3D T2 mapping: Impact of undersampling strategies and reconstruction techniques

Author

Listed:
  • Dan Zhu
  • Haiyan Ding
  • M Muz Zviman
  • Henry Halperin
  • Michael Schär
  • Daniel A Herzka

Abstract

Purpose: We aim to determine an advantageous approach for the acceleration of high spatial resolution 3D cardiac T2 relaxometry data by comparing the performance of different undersampling patterns and reconstruction methods over a range of acceleration rates. Methods: Multi-volume 3D high-resolution cardiac images were acquired fully and undersampled retrospectively using 1) optimal CAIPIRINHA and 2) a variable density random (VDR) sampling. Data were reconstructed using 1) multi-volume sensitivity encoding (SENSE), 2) joint-sparsity SENSE and 3) model-based SENSE. Four metrics were calculated on 3 naïve swine and 8 normal human subjects over a whole left-ventricular region of interest: root-mean-square error (RMSE) of image signal intensity, RMSE of T2, the bias of mean T2, and standard deviation (SD) of T2. Fully sampled data and volume-by-volume SENSE with standard equally spaced undersampling were used as references. The Jaccard index calculated from one swine with acute myocardial infarction (MI) was used to demonstrate preservation of segmentation of edematous tissues with elevated T2. Results: In naïve swine and normal human subjects, all methods had similar performance when the net reduction factor (Rnet) 2.5, while VDR sampling with the joint-sparsity SENSE had the lowest bias of mean T2 (0.0–1.1ms) when Rnet>3. The RMSEs of parametric T2 values (9.2%-24.6%) were larger than for image signal intensities (5.2%-18.4%). In the swine with MI, VDR sampling with either joint-sparsity or model-based SENSE showed consistently higher Jaccard index for all Rnet (0.71–0.50) than volume-by-volume SENSE (0.68–0.30). Conclusions: Retrospective exploration of undersampling and reconstruction in 3D whole-heart T2 parametric mapping revealed that maps were more sensitive to undersampling than images, presenting a more stringent limiting factor on Rnet. The combination of VDR sampling patterns with model-based or joint-sparsity SENSE reconstructions were more robust for Rnet>3.

Suggested Citation

  • Dan Zhu & Haiyan Ding & M Muz Zviman & Henry Halperin & Michael Schär & Daniel A Herzka, 2021. "Accelerating whole-heart 3D T2 mapping: Impact of undersampling strategies and reconstruction techniques," PLOS ONE, Public Library of Science, vol. 16(9), pages 1-21, September.
  • Handle: RePEc:plo:pone00:0252777
    DOI: 10.1371/journal.pone.0252777
    as

    Download full text from publisher

    File URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0252777
    Download Restriction: no

    File URL: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0252777&type=printable
    Download Restriction: no

    File URL: https://libkey.io/10.1371/journal.pone.0252777?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0252777. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.