IDEAS home Printed from https://ideas.repec.org/a/plo/pone00/0238146.html
   My bibliography  Save this article

Estimating outflow facility parameters for the human eye using hypotensive pressure-time data

Author

Listed:
  • David W Smith
  • Chang-Joon Lee
  • Bruce S Gardiner

Abstract

We have previously developed a new theory for pressure dependent outflow from the human eye, and tested the model using experimental data at intraocular pressures above normal eye pressures. In this paper, we use our model to analyze a hypotensive pressure-time dataset obtained following application of a Honan balloon. Here we show that the hypotensive pressure-time data can be successfully analyzed using our proposed pressure dependent outflow model. When the most uncertain initial data point is removed from the dataset, then parameter estimates are close to our previous parameter estimates, but clearly parameter estimates are very sensitive to assumptions. We further show that (i) for a measured intraocular pressure-time curve, the estimated model parameter for whole eye surface hydraulic conductivity is primarily a function of the ocular rigidity, and (ii) the estimated model parameter that controls the rate of decrease of outflow with increasing pressure is primarily a function of the convexity of the monotonic pressure-time curve. Reducing parameter uncertainty could be accomplished using new technologies to obtain higher quality datasets, and by gathering additional data to better define model parameter ranges for the normal eye. With additional research, we expect the pressure dependent outflow analysis described herein may find applications in the differential diagnosis, prognosis and monitoring of the glaucomatous eye.

Suggested Citation

  • David W Smith & Chang-Joon Lee & Bruce S Gardiner, 2020. "Estimating outflow facility parameters for the human eye using hypotensive pressure-time data," PLOS ONE, Public Library of Science, vol. 15(8), pages 1-20, August.
  • Handle: RePEc:plo:pone00:0238146
    DOI: 10.1371/journal.pone.0238146
    as

    Download full text from publisher

    File URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0238146
    Download Restriction: no

    File URL: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0238146&type=printable
    Download Restriction: no

    File URL: https://libkey.io/10.1371/journal.pone.0238146?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    References listed on IDEAS

    as
    1. Joseph M Sherwood & Ester Reina-Torres & Jacques A Bertrand & Barnaby Rowe & Darryl R Overby, 2016. "Measurement of Outflow Facility Using iPerfusion," PLOS ONE, Public Library of Science, vol. 11(3), pages 1-29, March.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.

      More about this item

      Statistics

      Access and download statistics

      Corrections

      All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0238146. See general information about how to correct material in RePEc.

      If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

      If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

      If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

      For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .

      Please note that corrections may take a couple of weeks to filter through the various RePEc services.

      IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.