Author
Listed:
- Gellért Balázs Karvaly
- Michael N Neely
- Krisztián Kovács
- István Vincze
- Barna Vásárhelyi
- Roger W Jelliffe
Abstract
Background: The clinical value of therapeutic drug monitoring can be increased most significantly by integrating assay results into clinical pharmacokinetic models for optimal dosing. The correct weighting in the modeling process is 1/variance, therefore, knowledge of the standard deviations (SD) of each measured concentration is important. Because bioanalytical methods are heteroscedastic, the concentration-SD relationship must be modeled using assay error equations (AEE). We describe a methodology of establishing AEE’s for liquid chromatography-tandem mass spectrometry (LC-MS/MS) drug assays using carbamazepine, fluconazole, lamotrigine and levetiracetam as model analytes. Methods: Following method validation, three independent experiments were conducted to develop AEE’s using various least squares linear or nonlinear, and median-based linear regression techniques. SD’s were determined from zero concentration to the high end of the assayed range. In each experiment, precision profiles of 6 (“small” sample sets) or 20 (“large” sample sets) out of 24 independent, spiked specimens were evaluated. Combinatorial calculations were performed to attain the most suitable regression approach. The final AEE’s were developed by combining the SD’s of the assay results, established in 24 specimens/spiking level and using all spiking levels, into a single precision profile. The effects of gross hyperbilirubinemia, hemolysis and lipemia as laboratory interferences were investigated. Results: Precision profiles were best characterized by linear regression when 20 spiking levels, each having 24 specimens and obtained by performing 3 independent experiments, were combined. Theil’s regression with the Siegel estimator was the most consistent and robust in providing acceptable agreement between measured and predicted SD’s, including SD’s below the lower limit of quantification. Conclusions: In the framework of precision pharmacotherapy, establishing the AEE of assayed drugs is the responsibility of the therapeutic drug monitoring service. This permits optimal dosages by providing the correct weighting factor of assay results in the development of population and individual pharmacokinetic models.
Suggested Citation
Gellért Balázs Karvaly & Michael N Neely & Krisztián Kovács & István Vincze & Barna Vásárhelyi & Roger W Jelliffe, 2020.
"Development of a methodology to make individual estimates of the precision of liquid chromatography-tandem mass spectrometry drug assay results for use in population pharmacokinetic modeling and the o,"
PLOS ONE, Public Library of Science, vol. 15(3), pages 1-22, March.
Handle:
RePEc:plo:pone00:0229873
DOI: 10.1371/journal.pone.0229873
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0229873. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.