Author
Listed:
- David Diggin
- Ross Anderson
- Andrew J Harrison
Abstract
Research examining the reliability of stiffness measures during hopping has shown strong consistency in leg-spring stiffness (kleg), but high variability in joint stiffness (kjoint) measures. Sled-based systems (SBS) reduce movement degrees-of-freedom and are used to examine stretch-shortening cycle (SSC) function under controlled conditions. The aim of this study was to examine the reliability of kleg and kjoint during single-leg hopping within an SBSKinematic and kinetic data were collected on four occasions (Day_1, Day_2, Day_3 and Day_3Offset). Participants completed two trials of single-leg hopping at different frequencies (1.5, 2.2 and 3.0 Hz) while attached to an inclined-SBS. Stiffness was determined using models of leg-spring (kleg) and torsional (kjoint) stiffness. Statistical analysis identified absolute and relative measures of reliability. Results showed moderate reliability for kleg at 1.5 Hz between inter-day testing bouts, and weak consistency at 2.2 and 3.0 Hz. Examination of intra-day comparisons showed weak agreement for repeated measures of kleg at 1.5 and 2.2 Hz, but moderate agreement at 3.0 Hz. Limits in kleg reliability were accompanied by weak-to-moderate agreement in kjoint measures across inter- and intra-day testing bouts. Results showed limits in the reliability of stiffness measures relative to previous reports on overground hopping. Lack of consistency in kleg and kjoint may be due to the novelty of hopping within the current inclined-SBS. Constraints imposed on the hopping task resulting from SBS design (e.g. additional chair mass, restricting upper body movement) may have also influenced limits in kleg and kjoint reliability. Researchers should consider these findings when employing inclined-SBS of a similar design to examine SSC function.
Suggested Citation
David Diggin & Ross Anderson & Andrew J Harrison, 2019.
"Limits in reliability of leg-spring and joint stiffness measures during single-leg hopping within a sled-based system,"
PLOS ONE, Public Library of Science, vol. 14(12), pages 1-14, December.
Handle:
RePEc:plo:pone00:0225664
DOI: 10.1371/journal.pone.0225664
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0225664. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.