Author
Listed:
- Sanja Stevanović
- Dragan Stevanović
- Matthias Dehmer
Abstract
We studied previously optimal shape of external shading of windows in a cellular office with an outer edge modeled by a non-uniform rational basis spline (NURBS) curve whose control points were placed uniformly around western fin, overhang and eastern fin of the window, and whose depths were allowed to vary independently. We observed there that for each climate considered in the study there exists a shading shape close to the optimal one, but with a substantially simpler structure of control points for the NURBS curve. This simpler structure was reflected in partitioning control points into six groups such that all control points in the same group have equal depths, with groups corresponding to lower part of the western fin, upper part of the western fin, joint of the western fin and the overhang, internal part of the overhang, joint of the overhang and the eastern fin and the remaining part of the eastern fin. Here we confirm that shadings with control point structure restricted in such way can perform as well as shadings with unrestricted control points by optimising shape of external shading of windows in an apartment room for both restricted and unrestricted control point structure for the same range of climates, and showing that differences in heating and cooling demands between Pareto optimal shadings in both cases are negligibly small. This grouping of control points thus gives a simple and natural division of shading into a small number of basic constituents that have most impact on its heating and cooling demands. We further consider the convex hull of the Pareto front for shadings with restricted control points, as it contains shadings that minimise equivalent source energy in terms of the ratio of efficiencies and source energy conversion factors for district heating and cooling. We show that, in cases when depths of control point groups in convex hull shadings do not experience sudden changes between their extremal values, these depths can be fitted reasonably well by a sigmoid function that results in functional shadings that satisfactorily approximate heating and cooling demands of shadings in the Pareto front.
Suggested Citation
Sanja Stevanović & Dragan Stevanović & Matthias Dehmer, 2019.
"On optimal and near-optimal shapes of external shading of windows in apartment buildings,"
PLOS ONE, Public Library of Science, vol. 14(2), pages 1-23, February.
Handle:
RePEc:plo:pone00:0212710
DOI: 10.1371/journal.pone.0212710
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0212710. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.