IDEAS home Printed from https://ideas.repec.org/a/plo/pone00/0211676.html
   My bibliography  Save this article

The stability of long-segment and short-segment fixation for treating severe burst fractures at the thoracolumbar junction in osteoporotic bone: A finite element analysis

Author

Listed:
  • Yueh Wu
  • Chia-Hsien Chen
  • Fon-Yih Tsuang
  • Yi-Cheng Lin
  • Chang-Jung Chiang
  • Yi-Jie Kuo

Abstract

The majority of compressive vertebral fractures in osteoporotic bone occur at the level of the thoracolumbar junction. Immediate decompression is often required in order to reduce the extent of neurological damage. This study evaluated four fixation methods for decompression in patients with thoracolumbar burst fractures, and presented the most suitable method for osteoporotic patients. A finite element model of a T7–L5 spinal segment was created and subjected to an L1 corpectomy to simulate a serious burst fracture. Five models were tested: a) intact spine; 2) two segment fixation (TSF), 3) up-three segment fixation (UTSF), below-three segment fixation (BTSF), and four segment fixation (FSF). The ROM, stiffness and compression ratio of the fractured vertebra were recorded under various loading conditions. The results of this study showed that the ROM of the FSF model was the lowest, and the ROMs of UTSF and BTSF models were similar but still greater than the TSF model. Decreasing the BMD to simulate osteoporotic bone resulted in a ROM for the four instrumented models that was higher than the normal bone model. Of all models, the FSF model had the highest stiffness at T12-L2 in extension and lateral bending. Similarly, the compression ratio of the FSF model at L1 was also higher than the other instrumented models. In conclusion, FSF fixation is suggested for patients with osteoporotic thoracolumbar burst fractures. For patients with normal bone quality, both UTSF and BTSF fixation provide an acceptable stiffness in extension and lateral bending, as well as a favorable compression ratio at L1.

Suggested Citation

  • Yueh Wu & Chia-Hsien Chen & Fon-Yih Tsuang & Yi-Cheng Lin & Chang-Jung Chiang & Yi-Jie Kuo, 2019. "The stability of long-segment and short-segment fixation for treating severe burst fractures at the thoracolumbar junction in osteoporotic bone: A finite element analysis," PLOS ONE, Public Library of Science, vol. 14(2), pages 1-11, February.
  • Handle: RePEc:plo:pone00:0211676
    DOI: 10.1371/journal.pone.0211676
    as

    Download full text from publisher

    File URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0211676
    Download Restriction: no

    File URL: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0211676&type=printable
    Download Restriction: no

    File URL: https://libkey.io/10.1371/journal.pone.0211676?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0211676. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.