Author
Listed:
- Alemeh Sadrollahi
- Frank Nuesken
- Norbert Licht
- Christian Rübe
- Yvonne Dzierma
Abstract
The aim of our work is to provide the up-to-now missing information on the Siemens Artiste FFF 7 MV beam line using a Monte-Carlo model fit to the realistic dosimetric measurements at the linear accelerator in clinical use at our department. The main Siemens Artiste 6MV and FFF 7MV beams were simulated using the Geant4 toolkit. The simulations were compared with the measurements with an ionization chamber in a water phantom to verify the validation of simulation and tuning the primary electron parameters. Hereafter, other parameters such as surface dose, spectrum, electron contamination, symmetry, flatness/unflatness, slope, and characteristic off-axis changes were discussed for both Flat and FFF mode. The mean electron energy for the FFF beam was 8.8 MeV and 7.5 MeV for Flat 6 MV, the spread energy and spot size of the selected Gaussian distribution source were 0.4 MeV and 1mm, respectively. The dose rate of the FFF beam was 2.8 (2.96) times higher than for the flattened beam for a field size of 10×10 (20×20) cm2. The electron contamination has significant contribution to the surface dose especially for the flattened beam. The penumbra, surface dose and the mean energy of photons decrease by removing the flattening filter. Finally, the results show that off-axis changes have no strong effect on the mean energy of FFF beams, while this effect was more considerable for the flattened beam.
Suggested Citation
Alemeh Sadrollahi & Frank Nuesken & Norbert Licht & Christian Rübe & Yvonne Dzierma, 2019.
"Monte-Carlo simulation of the Siemens Artiste linear accelerator flat 6 MV and flattening-filter-free 7 MV beam line,"
PLOS ONE, Public Library of Science, vol. 14(1), pages 1-17, January.
Handle:
RePEc:plo:pone00:0210069
DOI: 10.1371/journal.pone.0210069
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0210069. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.