Author
Listed:
- Michael J Hutchinson
- Thomas A W Paulson
- Roger Eston
- Victoria L Goosey-Tolfrey
Abstract
Purpose: To examine the reliability of a perceptually-regulated maximal exercise test (PRETmax) to measure peak oxygen uptake (V˙O2peak) during handcycle exercise and to compare peak responses to those derived from a ramp-incremented protocol (RAMP). Methods: Twenty recreationally active individuals (14 male, 6 female) completed four trials across a 2-week period, using a randomised, counterbalanced design. Participants completed two RAMP protocols (20 W·min-1) in week 1, followed by two PRETmax in week 2, or vice versa. The PRETmax comprised five, 2-min stages clamped at Ratings of Perceived Exertion (RPE) 11, 13, 15, 17 and 20. Participants changed power output (PO) as often as required to maintain target RPE. Gas exchange variables (oxygen uptake, carbon dioxide production, minute ventilation), heart rate (HR) and PO were collected throughout. Differentiated RPE were collected at the end of each stage throughout trials. Results: For relative V˙O2peak, coefficient of variation (CV) was equal to 4.1% and 4.8%, with ICC(3,1) of 0.92 and 0.85 for repeated measures from PRETmax and RAMP, respectively. Measurement error was 0.15 L·min-1 and 2.11 ml·kg-1·min-1 in PRETmax and 0.16 L·min-1 and 2.29 ml·kg-1·min-1 during RAMP for determining absolute and relative V˙O2peak, respectively. The difference in V˙O2peak between PRETmax and RAMP was tending towards statistical significance (26.2 ± 5.1 versus 24.3 ± 4.0 ml·kg-1·min-1, P = 0.055). The 95% LoA were -1.9 ± 4.1 (-9.9 to 6.2) ml·kg-1·min-1. Conclusion: The PRETmax can be used as a reliable test to measure V˙O2peak during handcycle exercise in recreationally active participants. Whilst PRETmax tended towards significantly greater V˙O2peak values than RAMP, the difference is smaller than measurement error of determining V˙O2peak from PRETmax and RAMP.
Suggested Citation
Michael J Hutchinson & Thomas A W Paulson & Roger Eston & Victoria L Goosey-Tolfrey, 2017.
"Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test,"
PLOS ONE, Public Library of Science, vol. 12(7), pages 1-14, July.
Handle:
RePEc:plo:pone00:0181008
DOI: 10.1371/journal.pone.0181008
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0181008. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.