Author
Listed:
- Daniel Elenius Madsen
- Timothy C Nichols
- Elizabeth P Merricks
- Emily K Waters
- Bo Wiinberg
Abstract
Introduction: Canine models of severe haemophilia resemble their human equivalents both regarding clinical bleeding phenotype and response to treatment. Therefore pre-clinical studies in haemophilia dogs have allowed researchers to make valuable translational predictions regarding the potency and efficacy of new anti-haemophilia drugs (AHDs) in humans. To refine in vivo experiments and reduce number of animals, such translational studies are ideally preceded by in vitro prediction of compound efficacy using a plasma based global coagulation method. One such widely used method is the thrombin generation test (TGT). Unfortunately, commercially available TGTs are incapable of distinguishing between normal and haemophilia canine plasma, and therefore in vitro prediction using TGT has so far not been possible in canine plasma material. Aim: Establish a modified TGT capable of: 1) distinguishing between normal and haemophilia canine plasma, 2) monitoring correlation between canine plasma levels of coagulation factor VIII (FVIII) and IX (FIX) and thrombin generation, 3) assessing for agreement between compound activity and thrombin generation in ex vivo samples. Methods: A modified TGT assay was established where coagulation was triggered using a commercially available activated partial thromboplastin time reagent. Results: With the modified TGT a significant difference was observed in thrombin generation between normal and haemophilia canine plasma. A dose dependent thrombin generation was observed when assessing haemophilia A and B plasma spiked with dilution series of FVIII and FIX, respectively. Correlation between FVIII activity and thrombin generation was observed when analyzing samples from haemophilia A dogs dosed with canine FVIII. Limit of detection was 0.1% (v/v) FVIII or FIX. Conclusion: A novel modified TGT suitable for monitoring and prediction of replacement therapy efficacy in plasma from haemophilia A and B dogs was established.
Suggested Citation
Daniel Elenius Madsen & Timothy C Nichols & Elizabeth P Merricks & Emily K Waters & Bo Wiinberg, 2017.
"Global measurement of coagulation in plasma from normal and haemophilia dogs using a novel modified thrombin generation test – Demonstrated in vitro and ex vivo,"
PLOS ONE, Public Library of Science, vol. 12(4), pages 1-16, April.
Handle:
RePEc:plo:pone00:0175030
DOI: 10.1371/journal.pone.0175030
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0175030. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.