Author
Listed:
- Chung-Jung Lin
- Greta S P Mok
- Mang-Fen Tsai
- Wei-Ta Tsai
- Bang-Hung Yang
- Chun-Yuan Tu
- Tung-Hsin Wu
Abstract
Introduction: The purpose of the present study was to evaluate the influence of different variables on radiation dose and image quality based on a national database. Materials and Methods: Taiwan’s Ministry of Health and Welfare requested all radiology departments to complete a questionnaire for each of their CT scanners. Information gathered included all scanning parameters for CT head scans. For the present analysis, CT machines were divided into three subgroups: single slice CT (Group A); multi-detector CT (MDCT) with 2-64 slices (Group B); and MDCT with more than 64 slices (Group C). Correlations between computed tomography dose index (CTDI) and signal-to-noise ratio (SNR) with cumulated tube rotation number (CTW(n)) and cumulated tube rotation time (CTW(s)), and sub group analyses of CTDI and SNR across the three groups were performed. Results: CTDI values demonstrated a weak correlation (r = 0.33) with CTW(n) in Group A. SNR values demonstrated a weak negative correlation (r = -0.46) with CTW(n) in Group C. MDCT with higher slice numbers used more tube potential resulting in higher effective doses. There were both significantly lower CTDI and SNR values in helical mode than in axial mode in Group B, but not Group C. Conclusion: CTW(n) and CTW(s) did not influence radiation output. Helical mode is more often used in MDCT and results in both lower CTDI and SNR compared to axial mode in MDCT with less than 64 slices.
Suggested Citation
Chung-Jung Lin & Greta S P Mok & Mang-Fen Tsai & Wei-Ta Tsai & Bang-Hung Yang & Chun-Yuan Tu & Tung-Hsin Wu, 2015.
"National Survey of Radiation Dose and Image Quality in Adult CT Head Scans in Taiwan,"
PLOS ONE, Public Library of Science, vol. 10(6), pages 1-12, June.
Handle:
RePEc:plo:pone00:0131243
DOI: 10.1371/journal.pone.0131243
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0131243. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.