Author
Listed:
- Kaori Abe
- Yoshiko Hashimoto
- Shouki Yatsushiro
- Shohei Yamamura
- Mika Bando
- Yuka Hiroshima
- Jun-ichi Kido
- Masato Tanaka
- Yasuo Shinohara
- Toshihiko Ooie
- Yoshinobu Baba
- Masatoshi Kataoka
Abstract
Sandwich enzyme-linked immunosorbant assay (ELISA) using a 96-well plate is frequently employed for clinical diagnosis, but is time-and sample-consuming. To overcome these drawbacks, we performed a sandwich ELISA on a microchip. The microchip was made of cyclic olefin copolymer with 4 straight microchannels. For the construction of the sandwich ELISA for interleukin-6 (IL-6) or tumor necrosis factor-α (TNF-α), we used a piezoelectric inkjet printing system for the deposition and fixation of the 1st anti-IL-6 antibody or 1st anti-TNF-α antibody on the surface of the each microchannel. After the infusion of 2 µl of sample to the microchannel and a 20 min incubation, 2 µl of biotinylated 2nd antibody for either antigen was infused and a 10 min incubation. Then 2 µl of avidin-horseradish peroxidase was infused; and after a 5 min incubation, the substrate for peroxidase was infused, and the luminescence intensity was measured. Calibration curves were obtained between the concentration and luminescence intensity over the range of 0 to 32 pg/ml (IL-6: R2 = 0.9994, TNF-α: R2 = 0.9977), and the detection limit for each protein was 0.28 pg/ml and 0.46 pg/ml, respectively. Blood IL-6 and TNF-α concentrations of 5 subjects estimated from the microchip data were compared with results obtained by the conventional method, good correlations were observed between the methods according to linear regression analysis (IL-6: R2 = 0.9954, TNF-α: R2 = 0.9928). The reproducibility of the presented assay for the determination of the blood IL-6 and TNF-α concentration was comparable to that obtained with the 96-well plate. Simultaneous detection of blood IL-6 and TNF-α was possible by the deposition and fixation of each 1st antibody on the surface of a separate microchannel. This assay enabled us to determine simultaneously blood IL-6 and TNF-α with accuracy, satisfactory sensitivity, time saving ability, and low consumption of sample and reagents, and will be applicable to clinic diagnosis.
Suggested Citation
Kaori Abe & Yoshiko Hashimoto & Shouki Yatsushiro & Shohei Yamamura & Mika Bando & Yuka Hiroshima & Jun-ichi Kido & Masato Tanaka & Yasuo Shinohara & Toshihiko Ooie & Yoshinobu Baba & Masatoshi Kataok, 2013.
"Simultaneous Immunoassay Analysis of Plasma IL-6 and TNF-α on a Microchip,"
PLOS ONE, Public Library of Science, vol. 8(1), pages 1-8, January.
Handle:
RePEc:plo:pone00:0053620
DOI: 10.1371/journal.pone.0053620
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0053620. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.