Author
Listed:
- Dale J Hedges
- Toumy Guettouche
- Shan Yang
- Guney Bademci
- Ashley Diaz
- Ashley Andersen
- William F Hulme
- Sara Linker
- Arpit Mehta
- Yvonne J K Edwards
- Gary W Beecham
- Eden R Martin
- Margaret A Pericak-Vance
- Stephan Zuchner
- Jeffery M Vance
- John R Gilbert
Abstract
Despite the ever-increasing throughput and steadily decreasing cost of next generation sequencing (NGS), whole genome sequencing of humans is still not a viable option for the majority of genetics laboratories. This is particularly true in the case of complex disease studies, where large sample sets are often required to achieve adequate statistical power. To fully leverage the potential of NGS technology on large sample sets, several methods have been developed to selectively enrich for regions of interest. Enrichment reduces both monetary and computational costs compared to whole genome sequencing, while allowing researchers to take advantage of NGS throughput. Several targeted enrichment approaches are currently available, including molecular inversion probe ligation sequencing (MIPS), oligonucleotide hybridization based approaches, and PCR-based strategies. To assess how these methods performed when used in conjunction with the ABI SOLID3+, we investigated three enrichment techniques: Nimblegen oligonucleotide hybridization array-based capture; Agilent SureSelect oligonucleotide hybridization solution-based capture; and Raindance Technologies' multiplexed PCR-based approach. Target regions were selected from exons and evolutionarily conserved areas throughout the human genome. Probe and primer pair design was carried out for all three methods using their respective informatics pipelines. In all, approximately 0.8 Mb of target space was identical for all 3 methods. SOLiD sequencing results were analyzed for several metrics, including consistency of coverage depth across samples, on-target versus off-target efficiency, allelic bias, and genotype concordance with array-based genotyping data. Agilent SureSelect exhibited superior on-target efficiency and correlation of read depths across samples. Nimblegen performance was similar at read depths at 20× and below. Both Raindance and Nimblegen SeqCap exhibited tighter distributions of read depth around the mean, but both suffered from lower on-target efficiency in our experiments. Raindance demonstrated the highest versatility in assay design.
Suggested Citation
Dale J Hedges & Toumy Guettouche & Shan Yang & Guney Bademci & Ashley Diaz & Ashley Andersen & William F Hulme & Sara Linker & Arpit Mehta & Yvonne J K Edwards & Gary W Beecham & Eden R Martin & Marga, 2011.
"Comparison of Three Targeted Enrichment Strategies on the SOLiD Sequencing Platform,"
PLOS ONE, Public Library of Science, vol. 6(4), pages 1-8, April.
Handle:
RePEc:plo:pone00:0018595
DOI: 10.1371/journal.pone.0018595
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0018595. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.