Performance testing of solar heating systems and solar collectors according to International Standard Test procedures require sophisticated and expensive elaborate set-ups. Outdoor collector testing is not feasible in countries with widely fluctuating solar radiation conditions. Indoor testing does not give its true performance when the equipment is situated outdoors. This paper reports on a simple test procedure where the performances of the flat plate, U-tube and heat pipe natural convection solar heaters and the heat pipe force convection solar heater, which were tested on different days, were compared as if they were simultaneously tested side by side. The procedure allowed: (i) the maximum hot water storage temperature that could be achieved by the system over a long period of time without any water draw-off at all, (ii) overnight water temperature drop in the storage tank and (iii) expected end-of-day water temperature and mean system efficiency when water is completely drained down (draw-off) in the evening. Maximum temperatures reached for the natural convection heat pipe, force convection heat pipe, flat plate and U-tube system were 100, 84, 65 and 50°C, respectively. Overnight temperature drops due to standing tank loss and reverse flow were presented and found to be dependent upon initial tank temperature. By pro-rating all the results to reflect on the same area/volume ratio, the expected water temperature rise for the U-tube, forced convection heat pipe, flat plate and natural convection heat pipe systems was 13.6, 17.6, 20.6 and 28.4°C, respectively. Copyright , Oxford University Press.
Suggested Citation
K.S. Ong, 2011.
"Experimental comparative performance testing of solar water heaters,"
International Journal of Low-Carbon Technologies, Oxford University Press, vol. 6(4), pages 270-276, June.
Handle:
RePEc:oup:ijlctc:v:6:y:2011:i:4:p:270-276
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:oup:ijlctc:v:6:y:2011:i:4:p:270-276. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Oxford University Press (email available below). General contact details of provider: https://academic.oup.com/ijlct .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.