Author
Listed:
- Gil-Ho Lee
(Harvard University
Pohang University of Science and Technology)
- Dmitri K. Efetov
(The Barcelona Institute of Science and Technology)
- Woochan Jung
(Pohang University of Science and Technology)
- Leonardo Ranzani
(Raytheon BBN Technologies)
- Evan D. Walsh
(Massachusetts Institute of Technology
Harvard University)
- Thomas A. Ohki
(Raytheon BBN Technologies)
- Takashi Taniguchi
(National Institute for Materials Science)
- Kenji Watanabe
(National Institute for Materials Science)
- Philip Kim
(Harvard University)
- Dirk Englund
(Harvard University)
- Kin Chung Fong
(Raytheon BBN Technologies)
Abstract
Sensitive microwave detectors are essential in radioastronomy1, dark-matter axion searches2 and superconducting quantum information science3,4. The conventional strategy to obtain higher-sensitivity bolometry is the nanofabrication of ever smaller devices to augment the thermal response5–7. However, it is difficult to obtain efficient photon coupling and to maintain the material properties in a device with a large surface-to-volume ratio owing to surface contamination. Here we present an ultimately thin bolometric sensor based on monolayer graphene. To utilize the minute electronic specific heat and thermal conductivity of graphene, we develop a superconductor–graphene–superconductor Josephson junction8–13 bolometer embedded in a microwave resonator with a resonance frequency of 7.9 gigahertz and over 99 per cent coupling efficiency. The dependence of the Josephson switching current on the operating temperature, charge density, input power and frequency shows a noise-equivalent power of 7 × 10−19 watts per square-root hertz, which corresponds to an energy resolution of a single 32-gigahertz photon14, reaching the fundamental limit imposed by intrinsic thermal fluctuations at 0.19 kelvin. Our results establish that two-dimensional materials could enable the development of bolometers with the highest sensitivity allowed by the laws of thermodynamics.
Suggested Citation
Gil-Ho Lee & Dmitri K. Efetov & Woochan Jung & Leonardo Ranzani & Evan D. Walsh & Thomas A. Ohki & Takashi Taniguchi & Kenji Watanabe & Philip Kim & Dirk Englund & Kin Chung Fong, 2020.
"Graphene-based Josephson junction microwave bolometer,"
Nature, Nature, vol. 586(7827), pages 42-46, October.
Handle:
RePEc:nat:nature:v:586:y:2020:i:7827:d:10.1038_s41586-020-2752-4
DOI: 10.1038/s41586-020-2752-4
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Citations
Citations are extracted by the
CitEc Project, subscribe to its
RSS feed for this item.
Cited by:
- Yablokov, A.A. & Glushkov, E.I. & Pankratov, A.L. & Gordeeva, A.V. & Kuzmin, L.S. & Il’ichev, E.V., 2021.
"Resonant response drives sensitivity of Josephson escape detector,"
Chaos, Solitons & Fractals, Elsevier, vol. 148(C).
- Ladeynov, D.A. & Egorov, D.G. & Pankratov, A.L., 2023.
"Stochastic versus dynamic resonant activation to enhance threshold detector sensitivity,"
Chaos, Solitons & Fractals, Elsevier, vol. 171(C).
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:nat:nature:v:586:y:2020:i:7827:d:10.1038_s41586-020-2752-4. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.nature.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.