IDEAS home Printed from https://ideas.repec.org/a/nat/nature/v581y2020i7806d10.1038_s41586-020-2254-4.html
   My bibliography  Save this article

Liquid flow and control without solid walls

Author

Listed:
  • Peter Dunne

    (Université de Strasbourg, CNRS, ISIS
    Université de Strasbourg, CNRS, IPCMS UMR 7504)

  • Takuji Adachi

    (Université de Strasbourg, CNRS, ISIS
    University of Geneva)

  • Arvind Arun Dev

    (Université de Strasbourg, CNRS, IPCMS UMR 7504)

  • Alessandro Sorrenti

    (Université de Strasbourg, CNRS, ISIS
    ETH Zürich)

  • Lucas Giacchetti

    (Université de Strasbourg, CNRS, ISIS)

  • Anne Bonnin

    (Paul Scherrer Institut)

  • Catherine Bourdon

    (Université de Strasbourg, INSERM, EFS Grand-Est, BPPS UMR-S1255, FMTS)

  • Pierre H. Mangin

    (Université de Strasbourg, INSERM, EFS Grand-Est, BPPS UMR-S1255, FMTS)

  • J. M. D. Coey

    (Trinity College)

  • Bernard Doudin

    (Université de Strasbourg, CNRS, IPCMS UMR 7504)

  • Thomas M. Hermans

    (Université de Strasbourg, CNRS, ISIS)

Abstract

When miniaturizing fluidic circuitry, the solid walls of the fluid channels become increasingly important1 because they limit the flow rates achievable for a given pressure drop, and they are prone to fouling2. Approaches for reducing the wall interactions include hydrophobic coatings3, liquid-infused porous surfaces4–6, nanoparticle surfactant jamming7, changes to surface electronic structure8, electrowetting9,10, surface tension pinning11,12 and use of atomically flat channels13. A better solution may be to avoid the solid walls altogether. Droplet microfluidics and sheath flow achieve this but require continuous flow of the central liquid and the surrounding liquid1,14. Here we demonstrate an approach in which aqueous liquid channels are surrounded by an immiscible magnetic liquid, both of which are stabilized by a quadrupolar magnetic field. This creates self-healing, non-clogging, anti-fouling and near-frictionless liquid-in-liquid fluidic channels. Manipulation of the field provides flow control, such as valving, splitting, merging and pumping. The latter is achieved by moving permanent magnets that have no physical contact with the liquid channel. We show that this magnetostaltic pumping method can be used to transport whole human blood with very little damage due to shear forces. Haemolysis (rupture of blood cells) is reduced by an order of magnitude compared with traditional peristaltic pumping, in which blood is mechanically squeezed through a plastic tube. Our liquid-in-liquid approach provides new ways to transport delicate liquids, particularly when scaling channels down to the micrometre scale, with no need for high pressures, and could also be used for microfluidic circuitry.

Suggested Citation

  • Peter Dunne & Takuji Adachi & Arvind Arun Dev & Alessandro Sorrenti & Lucas Giacchetti & Anne Bonnin & Catherine Bourdon & Pierre H. Mangin & J. M. D. Coey & Bernard Doudin & Thomas M. Hermans, 2020. "Liquid flow and control without solid walls," Nature, Nature, vol. 581(7806), pages 58-62, May.
  • Handle: RePEc:nat:nature:v:581:y:2020:i:7806:d:10.1038_s41586-020-2254-4
    DOI: 10.1038/s41586-020-2254-4
    as

    Download full text from publisher

    File URL: https://www.nature.com/articles/s41586-020-2254-4
    File Function: Abstract
    Download Restriction: Access to the full text of the articles in this series is restricted.

    File URL: https://libkey.io/10.1038/s41586-020-2254-4?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Rajamani, Keerthivasan & Juffermans, Eva & Granelli, Luca & De Cuadra Rabaneda, Ana & Rohlfs, Wilko & ter Brake, Marcel & van der Meer, Theo & Shahi, Mina, 2024. "A low-frequency ferrohydrodynamic pump for a magneto-caloric refrigerator," Applied Energy, Elsevier, vol. 355(C).

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:nat:nature:v:581:y:2020:i:7806:d:10.1038_s41586-020-2254-4. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.nature.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.