IDEAS home Printed from https://ideas.repec.org/a/nat/nature/v572y2019i7770d10.1038_s41586-019-1491-x.html
   My bibliography  Save this article

Ionic-surfactant-mediated electro-dewetting for digital microfluidics

Author

Listed:
  • Jia Li

    (University of California, Los Angeles (UCLA))

  • Noel S. Ha

    (University of California, Los Angeles (UCLA)
    University of California, Los Angeles (UCLA))

  • Tingyi ‘Leo’ Liu

    (University of California, Los Angeles (UCLA)
    University of Massachusetts
    University of Massachusetts)

  • R. Michael Dam

    (University of California, Los Angeles (UCLA)
    University of California, Los Angeles (UCLA)
    University of California, Los Angeles (UCLA)
    University of California, Los Angeles (UCLA))

  • Chang-Jin ‘CJ’ Kim

    (University of California, Los Angeles (UCLA)
    University of California, Los Angeles (UCLA)
    University of California, Los Angeles (UCLA))

Abstract

The ability to manipulate droplets on a substrate using electric signals1—known as digital microfluidics—is used in optical2,3, biomedical4,5, thermal6 and electronic7 applications and has led to commercially available liquid lenses8 and diagnostics kits9,10. Such electrical actuation is mainly achieved by electrowetting, with droplets attracted towards and spreading on a conductive substrate in response to an applied voltage. To ensure strong and practical actuation, the substrate is covered with a dielectric layer and a hydrophobic topcoat for electrowetting-on-dielectric (EWOD)11-13; this increases the actuation voltage (to about 100 volts) and can compromise reliability owing to dielectric breakdown14, electric charging15 and biofouling16. Here we demonstrate droplet manipulation that uses electrical signals to induce the liquid to dewet, rather than wet, a hydrophilic conductive substrate without the need for added layers. In this electrodewetting mechanism, which is phenomenologically opposite to electrowetting, the liquid–substrate interaction is not controlled directly by electric field but instead by field-induced attachment and detachment of ionic surfactants to the substrate. We show that this actuation mechanism can perform all the basic fluidic operations of digital microfluidics using water on doped silicon wafers in air, with only ±2.5 volts of driving voltage, a few microamperes of current and about 0.015 times the critical micelle concentration of an ionic surfactant. The system can also handle common buffers and organic solvents, promising a simple and reliable microfluidic platform for a broad range of applications.

Suggested Citation

  • Jia Li & Noel S. Ha & Tingyi ‘Leo’ Liu & R. Michael Dam & Chang-Jin ‘CJ’ Kim, 2019. "Ionic-surfactant-mediated electro-dewetting for digital microfluidics," Nature, Nature, vol. 572(7770), pages 507-510, August.
  • Handle: RePEc:nat:nature:v:572:y:2019:i:7770:d:10.1038_s41586-019-1491-x
    DOI: 10.1038/s41586-019-1491-x
    as

    Download full text from publisher

    File URL: https://www.nature.com/articles/s41586-019-1491-x
    File Function: Abstract
    Download Restriction: Access to the full text of the articles in this series is restricted.

    File URL: https://libkey.io/10.1038/s41586-019-1491-x?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Yuqing Chang & Yuqian Wang & Wen Li & Zewen Wei & Shichuan Tang & Rui Chen, 2023. "Mechanisms, Techniques and Devices of Airborne Virus Detection: A Review," IJERPH, MDPI, vol. 20(8), pages 1-30, April.

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:nat:nature:v:572:y:2019:i:7770:d:10.1038_s41586-019-1491-x. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.nature.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.