Author
Listed:
- Qi Yang
(Purdue University
Purdue University
Purdue University
Purdue University)
- Ángel Enríquez
(Purdue University
Purdue University
Purdue University)
- Dillon Devathasan
(Purdue University)
- Craig A. Thompson
(Purdue University)
- Dillan Nayee
(Purdue University
Purdue University)
- Ryan Harris
(Purdue University
Purdue University)
- Douglas Satoski
(Purdue University
Purdue University)
- Barnabas Obeng-Gyasi
(Purdue University
Purdue University)
- Albert Lee
(Goodman Campbell Brain and Spine)
- R. Timothy Bentley
(Purdue University)
- Hyowon Lee
(Purdue University
Purdue University
Purdue University)
Abstract
Maintaining the patency of indwelling drainage devices is critical in preventing further complications following an intraventricular hemorrhage (IVH) and other chronic disease management. Surgeons often use drainage devices to remove blood and cerebrospinal fluid but these catheters frequently become occluded with hematoma. Using an implantable magnetic microactuator, we created a self-clearing catheter that can generate large enough forces to break down obstructive blood clots by applying time-varying magnetic fields. In a blood-circulating model, our self-clearing catheters demonstrated a > 7x longer functionality than traditional catheters (211 vs. 27 min) and maintained a low pressure for longer periods (239 vs. 79 min). Using a porcine IVH model, the self-clearing catheters showed a greater survival rate than control catheters (86% vs. 0%) over the course of 6 weeks. The treated animals also had significantly smaller ventricle sizes 1 week after implantation compared to the control animals with traditional catheters. Our results suggest that these magnetic microactuator-embedded smart catheters can expedite the removal of blood from the ventricles and potentially improve the outcomes of critical patients suffering from often deadly IVH.
Suggested Citation
Qi Yang & Ángel Enríquez & Dillon Devathasan & Craig A. Thompson & Dillan Nayee & Ryan Harris & Douglas Satoski & Barnabas Obeng-Gyasi & Albert Lee & R. Timothy Bentley & Hyowon Lee, 2022.
"Application of magnetically actuated self-clearing catheter for rapid in situ blood clot clearance in hemorrhagic stroke treatment,"
Nature Communications, Nature, vol. 13(1), pages 1-11, December.
Handle:
RePEc:nat:natcom:v:13:y:2022:i:1:d:10.1038_s41467-022-28101-5
DOI: 10.1038/s41467-022-28101-5
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:nat:natcom:v:13:y:2022:i:1:d:10.1038_s41467-022-28101-5. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.nature.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.