Author
Listed:
- Muhammad Bilal Shahnawaz
- Hassan Dawood
Abstract
Myocardial infarction (MI), usually termed as heart attack, is one of the main cardiovascular diseases that occur due to the blockage of coronary arteries. This blockage reduces the blood supply to heart muscles, and a prolonged deficiency of blood supply causes the death of heart muscles leading to a heart attack that may cause death. An electrocardiogram (ECG) is used to diagnose MI as it causes variations like ST-T changes in the recorded ECG. Manual inspection of these variations is a tedious task and also requires expertise as the variations produced by MI are often very short in duration with a low amplitude. Hence, these changes may be misinterpreted, leading to delayed diagnosis and appropriate treatment. Therefore, computer-aided analysis of ECG may help to detect MI automatically. In this study, a robust deep learning model is proposed to detect MI based on heart rate variability (HRV) analysis of ECG signals from a single lead. Ultrashort-term HRV analysis is performed to compute HRV analysis features from time-domain and frequency-domain parameters through power spectral density estimations. Nonlinear HRV parameters are also computed using Poincare Plot, Recurrence Analysis, and Detrended Fluctuation Analysis. A finely tuned customized artificial neural network (ANN) algorithm is applied on 23 HRV features for MI detection and classification. The K-fold validation method is used to avoid any biases in results and reported 99.1% accuracy, 100% sensitivity, 98.1% specificity, and 99.0% F 1 for MI detection, whereas 98.85% accuracy, 97.40% sensitivity, 99.05% specificity, and 97.70% F 1 score is achieved for classification. Furthermore, the ANN algorithm completed its execution in just 59 seconds that indicates the efficiency of the proposed ANN model. The overall performance in terms of computed evaluation matrices and execution time indicates the robustness and cost-effectiveness of the proposed methodology. Thus, the proposed model can be used for high-performance MI detection, even in wearable devices.
Suggested Citation
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:hin:jnlmpe:6455053. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Mohamed Abdelhakeem (email available below). General contact details of provider: https://www.hindawi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.