IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v15y2023i3p2546-d1052631.html
   My bibliography  Save this article

On the Performance of Diffuse Ceiling Ventilation in Classrooms: A Pre-Occupancy Study at a School in Southern Sweden

Author

Listed:
  • Too-Chukwu Cyracus Ogbuagu

    (Department of Building Engineering, Energy Systems and Sustainability Science, University of Gävle, Kungsbäcksvagen 47, 801 76 Gävle, Sweden)

  • Elisabet Linden

    (Department of Building Engineering, Energy Systems and Sustainability Science, University of Gävle, Kungsbäcksvagen 47, 801 76 Gävle, Sweden)

  • Douglas MacCutcheon

    (SG Ecophon AB, Box 500, 265 03 Hyllinge, Sweden)

  • Erling Nilsson

    (SG Ecophon AB, Box 500, 265 03 Hyllinge, Sweden)

  • Torbjorn Persson

    (SG Ecophon AB, Box 500, 265 03 Hyllinge, Sweden)

  • Alan Kabanshi

    (Department of Building Engineering, Energy Systems and Sustainability Science, University of Gävle, Kungsbäcksvagen 47, 801 76 Gävle, Sweden)

Abstract

The implementation and application of diffused ceiling ventilation (DCV) is gradually gaining momentum, especially in Denmark, Finland, and the Netherlands. In countries such as Sweden, the application is limited despite the favorable conditions for implementation. The current study investigates the performance of DCV and mixing ventilation in a pre-occupancy field study for newly renovated classrooms in Southern Sweden. Two classrooms at the school were installed with diffuse ceiling ventilation while the rest had mixing ventilation. The objective of the study was to compare and evaluate the ventilation performance in terms of indoor environmental quality parameters such as thermal comfort, air quality indexes, airflow, and temperature distribution. Pre-occupancy measurements were performed in two classrooms with similar room characteristics, with one room running under mixing ventilation and the other under DCV. Constant temperature anemometers, thermocouples, and INNOVA thermal comfort were used to measure the indoor air speeds, temperature, and thermal comfort, respectively. Tracer gas measurements, with SF 6 , were performed to assess air quality. Additionally acoustic measurements were conducted to assess the acoustic benefits of DCV on reducing ventilation noise. The results demonstrate that DCV offers similar indoor environmental conditions to mixing ventilation but has better acoustic performance especially on reducing the ventilation noise. Indoor environmental conditions were very homogeneous under DCV with mixing ventilation showing tendencies for short circuit ventilation. This study demonstrates that DCV has a potential for implementation in Swedish schools with minimal system modification on existing ventilation and air distribution systems.

Suggested Citation

  • Too-Chukwu Cyracus Ogbuagu & Elisabet Linden & Douglas MacCutcheon & Erling Nilsson & Torbjorn Persson & Alan Kabanshi, 2023. "On the Performance of Diffuse Ceiling Ventilation in Classrooms: A Pre-Occupancy Study at a School in Southern Sweden," Sustainability, MDPI, vol. 15(3), pages 1-17, January.
  • Handle: RePEc:gam:jsusta:v:15:y:2023:i:3:p:2546-:d:1052631
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/15/3/2546/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/15/3/2546/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Alessandro Nocente & Tufan Arslan & Steinar Grynning & Francesco Goia, 2020. "CFD Study of Diffuse Ceiling Ventilation through Perforated Ceiling Panels," Energies, MDPI, vol. 13(8), pages 1-14, April.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Aner Martinez-Soto & Carlos Jimenez-Gallardo & Andrés Villarroel-Lopez & Alejandro Reyes-Riveros & Johanna Höhl, 2024. "Toward Sustainable Indoor Environments: Assessing the Impact of Thermal Insulation Measures on Air Quality in Buildings—A Case Study in Temuco, Chile," Sustainability, MDPI, vol. 16(2), pages 1-17, January.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Hou, Falin & Shen, Chenhui & Cheng, Qing, 2022. "Research on a new optimization method for airflow organization in breeding air conditioning with perforated ceiling ventilation," Energy, Elsevier, vol. 254(PB).
    2. Joanna Halibart & Klaudia Zwolińska & Marek Borowski & Marek Jaszczur, 2021. "Analysis of the Velocity Distribution in the Plenum Box with Various Entries," Energies, MDPI, vol. 14(12), pages 1-17, June.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:15:y:2023:i:3:p:2546-:d:1052631. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.