IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v11y2019i22p6205-d284146.html
   My bibliography  Save this article

Ventilation as an Indispensable Tool for Healthy Constructions: Comparison of Alicante’s Urban Railway Tunnels

Author

Listed:
  • Carlos Rizo-Maestre

    (Department of Architectural Constructions, University of Alicante, Ctra. San Vicente Del Raspeig S/N, 03690 San Vicente Del Raspeig (Alicante), Spain)

  • Víctor Echarri-Iribarren

    (Department of Architectural Constructions, University of Alicante, Ctra. San Vicente Del Raspeig S/N, 03690 San Vicente Del Raspeig (Alicante), Spain)

  • Antonio Galiano-Garrigós

    (Department of Architectural Constructions, University of Alicante, Ctra. San Vicente Del Raspeig S/N, 03690 San Vicente Del Raspeig (Alicante), Spain)

Abstract

The majority of scientific agencies in the field of medicine and health, including the World Health Organization, consider radon gas a very harmful element for humans. This element, in its gaseous state, is radioactive and is present in almost all land in which buildings are implanted, especially in granitic soils, which present higher levels of radon gas. Nongranitic soils have traditionally been considered to have low radon levels. In addition to the contributions made by this article, it is very relevant that there are many countries, including Spain, in which the technical codes for their construction regulations do not include the maximum radon dose that a building can hold so that it is not harmful to humans nor do they hold the measures necessary to remedy excessive accumulation. The main objective of this research is to demonstrate the need for ventilation in buried works. To do this, a comparison is made between two railway tunnels in the urban fabric of the city of Alicante: one of them is in operation (Benacantil Mount) and the other is in the excavation phase (Serra Grossa). When underground railway installations are planned, they are equipped with large air ventilation systems due to the pollutants generated by ground exposure. These mechanical systems consist of suction turbines that expel the air to the outside. Research shows that radon gas is an indicator of an area’s air quality. In addition, ventilation in railway tunnels (mechanical and natural) allows for air renewal and improves the air quality.

Suggested Citation

  • Carlos Rizo-Maestre & Víctor Echarri-Iribarren & Antonio Galiano-Garrigós, 2019. "Ventilation as an Indispensable Tool for Healthy Constructions: Comparison of Alicante’s Urban Railway Tunnels," Sustainability, MDPI, vol. 11(22), pages 1-20, November.
  • Handle: RePEc:gam:jsusta:v:11:y:2019:i:22:p:6205-:d:284146
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/11/22/6205/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/11/22/6205/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Carlos Rizo Maestre & Victor Echarri Iribarren, 2019. "The Importance of Checking Indoor Air Quality in Underground Historic Buildings Intended for Tourist Use," Sustainability, MDPI, vol. 11(3), pages 1-17, January.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Marco Huymajer & Matthias Woegerbauer & Leopold Winkler & Alexandra Mazak-Huemer & Hubert Biedermann, 2022. "An Interdisciplinary Systematic Review on Sustainability in Tunneling—Bibliometrics, Challenges, and Solutions," Sustainability, MDPI, vol. 14(4), pages 1-33, February.
    2. Carlos Rizo-Maestre & Víctor Echarri-Iribarren, 2020. "Radon Gas in the City of Alicante. High Risk of Low Indoor Air Quality in Poorly Ventilated Buildings," IJERPH, MDPI, vol. 17(23), pages 1-25, November.
    3. Pranas Baltrėnas & Raimondas Grubliauskas & Vaidotas Danila, 2020. "Seasonal Variation of Indoor Radon Concentration Levels in Different Premises of a University Building," Sustainability, MDPI, vol. 12(15), pages 1-15, July.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Carlos Rizo-Maestre & Víctor Echarri-Iribarren, 2020. "Radon Gas in the City of Alicante. High Risk of Low Indoor Air Quality in Poorly Ventilated Buildings," IJERPH, MDPI, vol. 17(23), pages 1-25, November.
    2. Carlos Rizo-Maestre & Víctor Echarri-Iribarren & Raúl Prado-Govea & Francisco Pujol-López, 2019. "Radon Gas as an Indicator for Air Quality Control in Buried Industrial Architecture: Rehabilitation of the Old Británica Warehouses in Alicante for a Tourist Site," Sustainability, MDPI, vol. 11(17), pages 1-16, August.
    3. Pranas Baltrėnas & Raimondas Grubliauskas & Vaidotas Danila, 2020. "Seasonal Variation of Indoor Radon Concentration Levels in Different Premises of a University Building," Sustainability, MDPI, vol. 12(15), pages 1-15, July.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:11:y:2019:i:22:p:6205-:d:284146. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.