Author
Listed:
- Zuoxun Hou
(Beijing Institute of Mechanics & Electricity, Beijing 100190, China)
- Ruichen Yuan
(Beijing Institute of Mechanics & Electricity, Beijing 100190, China)
- Zihao Wang
(School of Instrumentation Science and Optoelectronic Engineering, Beihang University, Beijing 100191, China)
- Xiaorui Wei
(School of Instrumentation Science and Optoelectronic Engineering, Beihang University, Beijing 100191, China)
- Chujian Ren
(School of Instrumentation Science and Optoelectronic Engineering, Beihang University, Beijing 100191, China)
- Jiale Zhou
(School of Instrumentation Science and Optoelectronic Engineering, Beihang University, Beijing 100191, China)
- Xiaolei Qu
(School of Instrumentation Science and Optoelectronic Engineering, Beihang University, Beijing 100191, China)
Abstract
Breast cancer is a global health concern, emphasizing the need for early detection. However, current mammography struggles to effectively image dense breasts. Breast ultrasound can be an adjunctive method, but it is highly dependent on operator skill. Ultrasound computed tomography (USCT) reflection imaging provides high-quality 3D images, but often uses delay-and-sum (DAS) beamforming, which limits its image quality. This article proposes the integration of coherence-factor (CF) beamforming into ultrasound computed tomography (USCT) reflection imaging to enhance image quality. CF assesses the focus quality of beamforming by analyzing the signal coherence across different channels, assigning higher weights to high-quality focus points and thereby improving overall image quality. Numerical simulations and phantom experiments using our built USCT prototype were conducted to optimize the imaging parameters and assess and compare the image quality of CF and DAS beamforming. Numerical simulations demonstrated that CF beamforming can significantly enhance image quality. Phantom experiments with our prototype revealed that CF beamforming significantly improves image resolution (from 0.35 mm to 0.14 mm) and increases contrast ratio (from 24.54 dB to 63.28 dB). The integration of CF beamforming into USCT reflection imaging represents a substantial improvement in image quality, offering promise for enhanced breast cancer detection and imaging capabilities.
Suggested Citation
Zuoxun Hou & Ruichen Yuan & Zihao Wang & Xiaorui Wei & Chujian Ren & Jiale Zhou & Xiaolei Qu, 2024.
"Ultrasound Computed Tomography Reflection Imaging with Coherence-Factor Beamforming for Breast Tumor Early Detection,"
Mathematics, MDPI, vol. 12(7), pages 1-16, April.
Handle:
RePEc:gam:jmathe:v:12:y:2024:i:7:p:1106-:d:1371347
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jmathe:v:12:y:2024:i:7:p:1106-:d:1371347. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.