Author
Listed:
- Nicholas E. Protonotarios
(Department of Applied Mathematics and Theoretical Physics, University of Cambridge, Cambridge CB3 0WA, UK)
- George A. Kastis
(Mathematics Research Center, Academy of Athens, 11527 Athens, Greece
Institute of Nuclear and Radiological Science and Technology, Energy and Safety (INRASTES), National Center for Scientific Research “Demokritos”, 15310 Agia Paraskevi, Greece)
- Andreas D. Fotopoulos
(Neurosurgical Institute, University of Ioannina, 45500 Ioannina, Greece)
- Andreas G. Tzakos
(Section of Organic Chemistry and Biochemistry, Department of Chemistry, University of Ioannina, 45110 Ioannina, Greece)
- Dimitrios Vlachos
(Department of Economics, University of Peloponnese, 22100 Tripoli, Greece)
- Nikolaos Dikaios
(Mathematics Research Center, Academy of Athens, 11527 Athens, Greece)
Abstract
The effective resolution of positron emission tomography (PET) can be significantly degraded by patient motion during data acquisition. This is especially true in the thorax due to respiratory motion. This study concentrates on the improvement of motion correction algorithms both in terms of image quality and computational cost. In this paper, we present a novel motion-compensated image reconstruction (MCIR) algorithm based on a parabolic surrogate likelihood function instead of the loglikelihood function of the expectation maximization (EM) algorithm. The theoretical advantage of the parabolic surrogate algorithm lies within the fact that its loglikelihood is upper bounded by the EM loglikelihood, thus it will converge faster than EM. This is of particular importance in PET motion correction, where reconstructions are very computationally demanding. Relaxation parameters were also introduced to converge closer to the maximum likelihood (ML) solution and achieve lower noise levels. Image reconstructions with embedded relaxation parameters actually converged to better solutions than the corresponding ones without relaxation. Motion-compensated parabolic surrogates were indeed shown to accelerate convergence compared to EM, without reaching a limit cycle. Nonetheless, with the incorporation of ordered subsets in the reconstruction setting, the improvement was less evident.
Suggested Citation
Nicholas E. Protonotarios & George A. Kastis & Andreas D. Fotopoulos & Andreas G. Tzakos & Dimitrios Vlachos & Nikolaos Dikaios, 2022.
"Motion-Compensated PET Image Reconstruction via Separable Parabolic Surrogates,"
Mathematics, MDPI, vol. 11(1), pages 1-17, December.
Handle:
RePEc:gam:jmathe:v:11:y:2022:i:1:p:55-:d:1013181
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jmathe:v:11:y:2022:i:1:p:55-:d:1013181. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.